PRO HARMONY RANGES INSTALLATION OPTIONS Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that creates a seamless look within standard cabinetry. These ranges can be installed in a wall or island installation. BACKGUARDS When using the Flush Island Trim, Thermador recommends a minimum 12" (305 mm) rear clearance to a combustible surface (see Figure 1, Cabinet Clearances). Clearances from noncombustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and / or by the local authority having jurisdiction. NATURAL GAS OR LP Thermador Dual-Fuel Pro Harmony Ranges are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify that the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), order PALPKITHC. Field conversion must be done by qualified service personnel only. Please refer to the LP Conversion Instructions packed with product for further information. IMPORTANT We strongly recommend that a Thermador Professional Wall or Island Hood or Custom Insert be installed with all Thermador Pro Harmony Ranges. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Pro Harmony Ranges. Refer to the Ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories. Due to the high surface temperature output of the Pro Harmony Ranges, the HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation solutions for these ranges. The PH Professional Series Wall Hoods are also a viable option. PRO HARMONY® RANGES 36-INCH DUAL-FUEL PRD366GHU 36-INCH CUTOUT AND RANGE DIMENSIONS as de ned in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certi ed by CSA. Clearaansceds oef lenssethdanin12"t(h30e5"mNma) mtiuostnbaelaFppuroevledGas Code" (ANSI Z223.1, by the locCalucordreesnantdE/odr bityitohenl)o.caCl aleutahoraritny chaevsingfrom non-combustible materials jurisdiction. are not part of the ANSI Z21.1 scope and are not certi ed by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and/or by the local authority having jurisdiction. NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. 1.800.735.4328 | THERMADOR.COM 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

49
PRO HARMONY RANGES
1.800.735.4328
|
THERMADOR.COM
INSTALLATION OPTIONS
Thermador Pro Harmony
®
Ranges feature a
bold, professional design and a compact,
24-inch depth profile that creates a seamless
look within standard cabinetry. These ranges
can be installed in a wall or island installation.
BACKGUARDS
When using the Flush Island Trim, Thermador
recommends a minimum 12" (305 mm) rear
clearance to a combustible surface (see Figure
1, Cabinet Clearances). Clearances from non-
combustible materials are not part of the ANSI
Z21.1 scope and are not certified by CSA.
Clearances of less than 12" (305 mm) must be
approved by the local codes and / or by the
local authority having jurisdiction.
NATURAL GAS OR LP
Thermador Dual-Fuel Pro Harmony Ranges
are shipped by the factory to operate on
natural gas. They must be converted for use
with propane. Verify that the type of gas
being used at the installation site matches
the type of gas used by the appliance. If the
location / job site requires conversion from
natural gas to propane (LP), order PALPKITHC.
Field conversion must be done by qualified
service personnel only. Please refer to the LP
Conversion Instructions packed with product
for further information.
IMPORTANT
We strongly recommend that a Thermador
Professional Wall or Island Hood or Custom
Insert be installed with all Thermador Pro
Harmony Ranges. Downdraft ventilation should
not be used. Do not install a microwave-hood
combination above the cooktop, as these types
of units do not provide the proper ventilation
and are not suitable for use with Thermador
Pro Harmony Ranges. Refer to the Ventilation
section or www.Thermador.com for a complete
selection of Professional ventilation options,
blowers, and accessories.
Due to the high surface temperature
output of the Pro Harmony Ranges, the
HPWB Professional Series Wall Hoods or
the Professional Series Custom Inserts are
recommended ventilation solutions for these
ranges. The PH Professional Series Wall
Hoods are also a viable option.
36-INCH CUTOUT AND RANGE DIMENSIONS
PRO HARMONY
®
RANGES
36-INCH DUAL-FUEL
PRD366GHU
NOTE:
A 36-inch minimum clearance is required between the top of the
cooking surface and the bottom of an unprotected cabinet. A 30-inch
clearance can be used when the bottom of the wood or metal cabinet is
protected by not less than
1
/
4
inch of a flame retardant material covered with
not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless
steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper.
as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12” (305 mm) must be approved
by the local codes and/or by the local authority having
jurisdiction.