Thermador T36IT71FNS Design Guide - Freedom Refrigeration - Page 12

Freedom, Collection, Freedom Refrigeration - installation instructions

Page 12 highlights

FREEdOM REFRIGERATION FREEdOM® COLLECTION PLANNING INFORMATION ELECTRICAL SPECIFICATIONS The appliance comes with a 3-wire power supply cord. UL listed in the USA. The appliance requires a 3-wire receptacle that is fitted with a 10 Amp fuse or higher. Refer to the following table for max load details. APPLIANCE MAX LOAd 24-Inch Fresh Food Column 1.5 Amps 30-Inch Fresh Food Column 1.5 Amps 18-Inch Freezer Column* 3.06 Amps 24-Inch Freezer Column* 3.70 Amps 30-Inch Freezer Column* 4.20 Amps 36-Inch 2-Door Bottom Freezer* 4.9 Amps 36-Inch French Door Bottom Freezer 4.9 Amps 18-Inch Wine Preservation Column 0.81 Amps 24-Inch Wine Preservation Column 0.90 Amps *Including ice maker The receptacle must be installed by a licensed electrician only. For the installation position of the receptacle refer to diagram in Electrical Location. IMPORTANT A 4-conductor cord shall be used when the appliance is installed in an area where the local codes do not permit grounding through the neutral. Power supply cord must be replaced by a licensed electrician only. AddITIONAL GROUNdING PROCEdURE Some local regulations may require a separate ground. In such cases, the required accessory ground wire, clamp and screw must be purchased separately. Never ground the appliance to plastic plumbing lines, gas lines or water pipes. GROUNdING INSTRUCTION This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for the electric current. WARNING Improper connection of the equipment grounding conductor may result in electric shock. Have the appliance checked by a qualified electrician or service technician if you are in doubt as to whether the appliance has been properly grounded. WATER LOCATION A cold water connection is required for appliances which feature an ice maker or an ice water dispenser. The water pressure must be between 40 and 120 p.s.i. (2.758.25 bar). The installation must comply with local plumbing regulations. A separate shut-off valve must be installed for the appliance water connection. The shut-off valve for the water connection must not be behind the appliance. It is recommended to place the shut-off valve directly next to the appliance (base unit) or in another easily accessible location. When installing the water connection, observe the permitted installation areas for the water supply line. The supply line can be located at the side on the right (a), at the side on the left (b), or underneath (c). ELECTRICAL LOCATION SPLIT COLUMN INSTALLATION 18-Inch 24-Inch 30-Inch X 18" 24" 30" (457mm) (610mm) (762mm) Y 9" 12" 15" (229mm) (305mm) (381mm) SIdE-BY-SIdE INSTALLATION 1.800.735.4328 | THERMADOR.COM 221

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

221
1.800.735.4328
|
THERMADOR.COM
FREEDOM
®
COLLECTION
PLANNING INFORMATION
FREEDOM REFRIGERATION
ELECTRICAL SPECIFICATIONS
The appliance comes with a 3-wire power supply cord.
UL listed in the USA.
The appliance requires a 3-wire receptacle that is fitted with
a 10 Amp fuse or higher. Refer to the following table for max
load details.
The receptacle must be installed by a licensed electrician only.
For the installation position of the receptacle refer to diagram
in Electrical Location.
IMPORTANT
A 4-conductor cord shall be used when the appliance is
installed in an area where the local codes do not permit
grounding through the neutral. Power supply cord must be
replaced by a licensed electrician only.
ADDITIONAL GROUNDING PROCEDURE
Some local regulations may require a separate ground. In such
cases, the required accessory ground wire, clamp and screw
must be purchased separately.
Never ground the appliance to plastic plumbing lines, gas
lines or water pipes.
GROUNDING INSTRUCTION
This appliance must be grounded.
In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for the
electric current.
WARNING
Improper connection of the equipment grounding conductor
may result in electric shock. Have the appliance checked by a
qualified electrician or service technician if you are in doubt as
to whether the appliance has been properly grounded.
WATER LOCATION
A cold water connection is required for appliances which feature
an ice maker or an ice water dispenser.
The water pressure must be between 40 and 120 p.s.i. (2.75-
8.25 bar). The installation must comply with local plumbing
regulations.
A separate shut-off valve must be installed for the appliance
water connection.
The shut-off valve for the water connection must not be behind
the appliance. It is recommended to place the shut-off valve
directly next to the appliance (base unit) or in another easily
accessible location. When installing the water connection,
observe the permitted installation areas for the water supply line.
The supply line can be located at the side on the right (a), at the
side on the left (b), or underneath (c).
ELECTRICAL LOCATION
SIDE-BY-SIDE INSTALLATION
SPLIT COLUMN INSTALLATION
18-Inch
24-Inch
30-Inch
X
18"
(457mm)
24"
(610mm)
30"
(762mm)
Y
9"
(229mm)
12"
(305mm)
15"
(381mm)
APPLIANCE
MAX LOAD
24-Inch Fresh Food Column
1.5 Amps
30-Inch Fresh Food Column
1.5 Amps
18-Inch Freezer Column*
3.06 Amps
24-Inch Freezer Column*
3.70 Amps
30-Inch Freezer Column*
4.20 Amps
36-Inch 2-Door Bottom Freezer*
4.9 Amps
36-Inch French Door Bottom Freezer
4.9 Amps
18-Inch Wine Preservation Column
0.81 Amps
24-Inch Wine Preservation Column
0.90 Amps
*Including ice maker