Thermador VTD600P Installation instructions - Page 5

Plan The, Installation, Install Flexible, Blower In Remote, Location, Parts Supplied

Page 5 highlights

PARTS SUPPLIED These parts are included with your Flexible Blower: 2 - blower mounting legs* 1 - Parts Bag containing: (4) wood screws #10 x .50" (12.7mm)* (4) blower mount brackets (1) strain relief bushing (8) screws #10 x .38" (9.7mm) (8) nuts #10 * For use when mounting Flexible Blower directly to Downdraft housing. (See Downdraft instruction manual.) PLAN THE I N S TA L L AT I O N If you choose to mount the Flexible Blower directly to the Downdraft housing: Remove the inlet cover (taped in place for shipping) and discard inlet cover. Refer to installation instructions in the Downdraft manual. If you choose to mount the Flexible Blower in an inline location, (such as the cabinet back, cabinet side, or floor joists) - follow the instructions below. INSTALL FLEXIBLE BLOWER IN REMOTE L O C AT I O N NOTE: THE FLEXIBLE BLOWER MUST BE INSTALLED WITHIN 4-FEET (1219mm) OF THE DOWNDRAFT'S ELECTRICAL PANEL. The Electrical Panel can be mounted directly to the Downdraft housing - or mounted in a remote location (always within 4-feet of the Flexible Blower). 10-3/8" (264) 12-3/4" (324) BLOWER INLET COVER 11-5/8" (295) 11-5/8" (295) 7-3/8" (187) 5-1/8" (130) INLET (from down- draft) 5" (127) 12-3/4" (324) 5-1/4" (133) OUTLET (to roof cap or wall cap) 1. Position inlet cover over blower wheel. Securely attach the inlet cover to the blower with 8 screws and 8 nuts from parts bag. Note that inlet cover is taped to blower for shipping. This tape may be removed. 2. Determine how the 8" (203mm) round INLET and OUTLET ductwork will connect to the Flexible Blower. Refer to installation instructions in the Downdraft manual. (4) MOUNTING BRACKETS attached with 1/4-20 X .50" (12.7mm) HEX HEAD SCREWS (6) MOUNTING BRACKET LOCATIONS 3. Remove the necessary 1/4-20 x .50" (12.7mm) hex head screws and attach 4 MOUNTING BRACKETS to the Flexible Blower - using 4 of the 6 POSSIBLE BRACKET MOUNTING LOCATIONS. 8-IN. (203mm) ROUND DUCT (from downdraft) MOUNTING SCREWS (not included) 8-IN. (203mm) ROUND DUCT (to roof cap or wall cap) 4. Mount Flexible Blower to back of cabinet, floor joist, or adequate framework (constructed by installer) with appropriate MOUNTING SCREWS (not included). 5. Connect 8" (203mm) ROUND DUCT from Downdraft housing to Flexible Blower inlet and from Flexible Blower outlet to roof or wall cap. For best performance: Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall studs, electrical wiring or plumbing for possible interference. 6. Use strain relief bushing (provided) to attach Flexible Blower wiring to wiring box on Downdraft's electrical panel and make wiring connections. (See Downdraft manual for instructions.) Page 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Page 5
12-3/4"
(324)
12-3/4"
(324)
5-1/8"
(130)
5-1/4"
(133)
5"
(127)
10-3/8"
(264)
11-5/8"
(295)
11-5/8"
(295)
7-3/8"
(187)
3.
Remove the necessary 1/4-20 x .50” (12.7mm) hex head screws and
attach
4 MOUNTING BRACKETS
to the Flexible Blower - using 4 of
the
6 POSSIBLE BRACKET MOUNTING LOCATIONS
.
4.
Mount Flexible Blower to back of cabinet, floor joist, or adequate
framework (constructed by installer) with appropriate
MOUNTING
SCREWS (not included)
.
5. Connect
8” (203mm) ROUND DUCT
from Downdraft housing to
Flexible Blower inlet and from Flexible Blower outlet to roof or wall
cap.
For best performance: Choose the ducting option which allows the
shortest length of ductwork and a minimum number of elbows and
transitions. Check location of floor joists, wall studs, electrical wiring
or plumbing for possible interference.
6.
Use strain relief bushing (provided) to attach Flexible Blower wiring
to wiring box on Downdraft’s electrical panel and make wiring
connections. (See Downdraft manual for instructions.)
(6) MOUNTING
BRACKET LOCATIONS
8-IN. (203mm)
ROUND
DUCT
(to roof cap
or wall cap)
8-IN. (203mm)
ROUND
DUCT
(from
downdraft)
MOUNTING SCREWS
(not included)
(4) MOUNTING
BRACKETS
attached with
1/4-20 X .50”
(12.7mm) HEX
HEAD SCREWS
PLAN THE
INSTALLATION
If you choose to mount the Flexible Blower directly to the Downdraft
housing: Remove the inlet cover (taped in place for shipping) and discard
inlet cover. Refer to installation instructions in the Downdraft manual.
If you choose to mount the Flexible Blower in an inline location, (such as
the cabinet back, cabinet side, or floor joists) - follow the instructions below.
INSTALL FLEXIBLE
BLOWER IN REMOTE
LOCATION
NOTE: THE FLEXIBLE BLOWER MUST BE INSTALLED WITHIN 4-FEET
(1219mm) OF THE DOWNDRAFT’S ELECTRICAL PANEL.
The Electrical
Panel can be mounted directly to the Downdraft housing - or mounted
in a remote location (always within 4-feet of the Flexible Blower).
1.
Position inlet cover over blower wheel. Securely attach the inlet cover
to the blower with 8 screws and 8 nuts from parts bag. Note that inlet
cover is taped to blower for shipping. This tape may be removed.
2.
Determine how the 8” (203mm) round
INLET
and
OUTLET
ductwork
will connect to the Flexible Blower. Refer to installation instructions
in the Downdraft manual.
INLET
(from down-
draft)
OUTLET
(to roof cap
or wall cap)
PARTS SUPPLIED
These parts are included with your Flexible Blower:
2 - blower mounting legs*
1 - Parts Bag containing:
(4) wood screws #10 x .50” (12.7mm)*
(4) blower mount brackets
(1) strain relief bushing
(8) screws #10 x .38” (9.7mm)
(8) nuts #10
*
For use when mounting Flexible Blower directly to Downdraft hous-
ing. (See Downdraft instruction manual.)
BLOWER
INLET
COVER