Toshiba IK-1000 Instruction Manual - Page 19
SENS sensitivity setting
UPC - 032017480407
View all Toshiba IK-1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
7.3 SENS (sensitivity setting) The sensitivity of this unit can be se to AUTO and MANUAL. Place the cursor "→" on MODE, press the [DATA UP] or [DATA DOWN] button, and select the desired mode from AUTO and MANUAL. AUTO: Automatically control the exposure time to get the set level. MANUAL: The camera operates with the fixed sensitivity. Lens automatic iris control function works except when long term exposure is set. 7.3.1 When Changing Setting of AUTO SENS Mode Up/down movement by MENU UP/DOWN Set by DATA UP/DOWN -- 1 SENS -- MODE AUTO FLICKER CMG MAX AGC MAX SS LONG MAX LEVEL PEAK/AVE AREA OFF CMG5 OFF OFF 0 AVERAGE PRESET A ɾSENS mode AUTO, MANUAL ɾDisplay of SCENE file ɾFlicker correction ON, OFF ɾSetting of maximum value of OFF, CMG1, CMG2, ʜ, CMG10 AUTO electronic multiplication ɾSetting of maximum value of OFF, 1dB, 2dB, ʜ, 18dB AUTO circuit gain ɾSetting of maximum value of AUTO long term exposure ɾAdjustment of AUTO SENS level ɾBrightness detection, average ɹvalue, peak mode selection OFF, 2FLD, 4FLD, ʜ, 256FLD -100, -99, ʜ, 0, 1, ʜ, 100 AVERAGE, PEAK ɾSelection of brightness detection area PRESET A, PRESET B, PRESET C, PRESET D, PRESET E, PRESET F, PRESET G - 19 -