Toshiba R100 Maintenance Manual - Page 62
Troubleshooting Procedures in or the 1.8 HDD Troubleshooting, Procedures
View all Toshiba R100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
2 Troubleshooting 2.4 System board Troubleshooting Table 2-3 D port status (6/6) D port status F11Dh Inspection items Initializing HW just before BOOT and waiting for the completion Treating CPU-related items FFFFh Treating after PRE_BOOT_SETUP Completion details Canceling NMI mask Examining the checksum of TIT Clearing IRT running flag for runtime Update checksum for runtime Checking whether a CPU, an HDD or other component have been upgraded Disabling a PC Card that is not being used Setting up battery safe mode Setting up date Waiting for the end of AC-Link initialization Updating DMI Wakeup factor and SM-BIOS structure table Closing configuration space of PCI devices Cache control Updating parameter block A Setting up the clock speed of the CPU to the appointed value by the Setup Waiting for the motor off of a disabled HDD Clearing power button status Enabling the power button Completion of checking DPORT status Check 1 If the D port status error code F11Ah is displayed, go to the 3.5" USB FDD Troubleshooting Procedures in Section 2.5 or the 1.8" HDD Troubleshooting Procedures in Section 2.6. Check 2 If any other D port status error code is displayed, perform Procedure 3. D port error statuses are following: Error code F160h F161h F162h F163h F11Eh Contents Timer CH2 error PIT error PIC #1 error PIC #2 error Clock generator setting error 2-26 PPORTEGE R100 Maintenance Manual (960-440)