Tripp Lite BCPRO600 Owner's Manual for BC Pro UPS 932621 - Page 5

Basic Operation - replacement battery

Page 5 highlights

200609130 93-2621 BCPro OM.qxd 9/20/2006 12:17 PM Page 5 Basic Operation continued MUTE/TEST Button: Silence the UPS On-Battery Alarm: Press and hold this button to silence the UPS on-battery alarm, a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery. Note: When the battery is nearly depleted, the low battery alarm-a continuous beep that cannot be silenced-will warn to shut down connected equipment immediately. Run a Self-Test: To run a self-test, leave connected equipment on. With the UPS plugged in and ON, press and hold the button until the UPS beeps (about 2 seconds) then release it. Self-Test Results: All LEDs will be lit and the UPS will emit several short beeps as it momentarily switches to battery to test charge and load capacity. The test will last up to 10 seconds. If the inverter is overloaded, the audible alarm will sound and the UPS will automatically shut down; if this happens, remove some of the load from the "UPS/Surge" outlets and run the self-test again. If the batteries are weak, the " " LED will stay lit and the UPS will continue to beep after the test. If this happens, let the UPS charge its batteries for 12 hours and repeat the test. If the condition persists, contact Tripp Lite for service. CAUTION: Do not unplug the UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into network connections. Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on. LINE POWER: This green light will illuminate whenever the UPS is ON and receiving normal AC line power. BATTERY POWER: This yellow light will illuminate when the UPS is providing equipment with battery power. REPLACE BATTERY: This red light will illuminate continuously after the UPS runs a self-test to indicate that the battery is weak. If it remains lit after allowing the UPS to charge for twelve hours and running a second self-test, contact Tripp Lite for service. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

5
MUTE/TEST Button:
Silence the UPS On-Battery Alarm:
Press and hold this button to
silence the UPS on-battery alarm, a series of short beeps followed by
a brief pause that is activated when the UPS is providing AC power
from battery. Note: When the battery is nearly depleted, the low
battery alarm—a continuous beep that cannot be silenced—will warn
to shut down connected equipment immediately.
Run a Self-Test:
To run a self-test, leave connected equipment on.
With the UPS plugged in and
ON
, press and hold the button until the
UPS beeps (about 2 seconds) then release it.
Self-Test Results:
All LEDs will be lit and the UPS will emit several
short beeps as it momentarily switches to battery to test charge and
load capacity. The test will last up to 10 seconds. If the inverter is
overloaded, the audible alarm will sound and the UPS will
automatically shut down; if this happens, remove some of the load
from the “UPS/Surge” outlets and run the self-test again. If the
batteries are weak, the “
” LED will stay lit and the UPS will
continue to beep after the test. If this happens, let the UPS charge its
batteries for 12 hours and repeat the test. If the condition persists,
contact Tripp Lite for service. CAUTION: Do not unplug the UPS to
test its batteries. This will remove safe electrical grounding and may
introduce a damaging surge into network connections.
Basic Operation
continued
All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on.
LINE POWER:
This green light will illuminate whenever the UPS is
ON
and receiving normal AC line power.
BATTERY POWER:
This yellow light will illuminate when the UPS is
providing equipment with battery power.
REPLACE BATTERY:
This red light will illuminate continuously after
the UPS runs a self-test to indicate that the battery is weak. If it remains lit
after allowing the UPS to charge for twelve hours and running a second
self-test, contact Tripp Lite for service.