URC Vivido-Dimmers Master Neutral Dimmer Manual - Page 2

master, see How to Identify, Common Wires IMPORTANT! How to identify Common Wires, Two

Page 2 highlights

Single Location Control Installation (requires one Master dimmer) 11.31 11..42 Black - Hot Tag Bare White Black To Light Identify existing wiring (This switch will be a single-pole) and tag "Hot" wire. Use Disconnect existing switch and remove. voltage tester as necessary to confirm "Hot" wire (Voltage will be present at the "Hot" wire when the lights are off). 11..64 TOP Hot Black 120V 11..53 White Master Black Green Tag Black Red Black White Connect master dimmer as shown by connecting black wire of dimmer to tagged "Hot" wire. Red wire must be connected to the wire that goes to the light. Red MASTER DIMMER Green White Light Fixture Gently push dimmer into place and secure with mounting screws. Make sure disconnect switch at bottom of master is fully pushed in Neutral Ground White Two Location Control Installation (requires one Master and one Accessory) 22..11 Black Red Bare Tag Black 2.2 White Black Red Bare Black Tag White 22..43 Accessory LOCATION A Black Tag Red Black ACCESSORY Green White MASTER DIMMER ACCESSORY DIMMER MASTER DIMMER Identify existing wiring (both existing switches will be "3-way") Tag common wire on both 3-Way switches (see "How to Identify Common Wires" section*) 2.45 Master White Red Green Black Tag Red White Black Black NOTE: The Circuit Breaker must be turned "ON" during this step and the switches must be set so that the light is OFF. Ensure that all wires are safely separated before turning the Circuit Breaker "ON." Connect the tester between the tagged common terminal and ground in one of the boxes to determine the location for the Accessory Dimmer. If the test indicates voltage then that will be Location A, and will be used for the Accessory Dimmer. If voltage is not present then the other 3-way location will be Location A. NOTE: Disconnect power after this step. Hot 120V Black Neutral Green Ground White White White LOCATION A Black Traveler Wires Red Black Green Ground White Disconnect existing switch and remove. Connect Accessory Dimmer in Location A as shown. Red White Light Fixture Three Location Control Installation (requires one Master and two Accessory dimmers) ACCESSORY DIMMER ACCESSORY DIMMER MASTER DIMMER 33..11 Red Black Red Bare Tag Black Tag White Identify existing wiring (4-way switches) Tag common wires on 4-Way switch. (see "How to Identify Common Wires" section*) Hot 120V Neutral Green Ground White White White LOCATION A Red Traveler Wires Black Green Ground White White 3..22 Black Accessory 4-Way Location Tag Red ACCESSORY Green White Black Red Red Black Traveler Wires Black White Black Green Ground White Connect the second Accessory Dimmer (4-way switch) as shown. White Light Fixture IMPORTANT! How to identify Common Wires* Two location: Each switch will have insulated wires connected to three terminal screws plus a green or bare wire connected to a green terminal screw. The three terminals are usually one dark colored screw and two light colored screws (ignore the Green screw). Alternatively, the three screws may be the same color and one will be marked COMMON or COM Find the wires connected to the dark or COMMON screws. Usually these wires are black but may be red or blue. Tag these wires on both switches to identify when wiring. Three location: Two of the existing switches will be 3-way. The 3-way switches will be located at each end of the circuit with a 4-way switch in between. TAG the two 3-way switches as in the Two Location Control section. The 4-Way switch has 4 insulated wires connected to 4 terminal screws. VERY IMPORTANT - TAG two same color insulated wires, which are connected to screws of opposite colors. Refer to 1.4 to push dimmers into place. Universal Remote Control, Inc. 500 Mamaroneck Ave. Harrison, NY 10528 (914) 835-4484 [email protected] www.UniversalRemote.com RFAL-DIMR-U-EN (REV. A)

  • 1
  • 2
  • 3

Single Location Control Installation (requires one Master dimmer)
Identify existing wiring (This switch will be a single-pole) and tag “Hot” wire. Use
voltage tester as necessary to confirm “Hot” wire (Voltage will be present at the
“Hot” wire when the lights are off).
Disconnect existing switch and remove.
Connect
master
dimmer as shown by connecting black
wire of dimmer to tagged “Hot” wire. Red wire must
be connected to the wire that goes to the light.
Gently push dimmer into place and secure with mounting screws. Make
sure disconnect switch at bottom of master is fully pushed in
Black
Red
Hot
Neutral
120V
Light Fixture
Green
Ground
MASTER
DIMMER
White
White
Two Location Control Installation (requires one Master and one Accessory)
Identify existing wiring (both existing switches will be “3-way”)
Tag common wire on both 3-Way switches
(see “How to Identify
Common Wires” section
*
)
NOTE: The Circuit Breaker must be turned “ON” during this step
and the switches must be set so that the light is OFF. Ensure
that all wires are safely separated before turning the Circuit
Breaker “ON.”
Connect the tester between the tagged common
terminal and ground in one of the boxes to determine the location
for the Accessory Dimmer.
If the test indicates voltage then that
will be Location A, and will be used for the Accessory Dimmer.
If voltage is not present then the other 3-way location will be
Location A.
NOTE:
Disconnect power after this step.
Disconnect existing switch and remove. Connect
Accessory Dimmer in Location A as shown.
Red
Black
Hot
Neutral
120V
Light Fixture
Green
Ground
Green
Ground
White
White
White
Red
White
Black
Traveler Wires
Black
ACCESSORY
DIMMER
MASTER
DIMMER
LOCATION A
Three Location Control Installation (requires one Master and two Accessory dimmers)
Identify existing wiring (4-way switches) Tag common
wires on 4-Way switch.
(see “How to Identify
Common Wires” section
*
)
Connect the second Accessory Dimmer (4-way switch) as shown.
IMPORTANT! How to identify Common Wires
*
Two location:
Each switch will have insulated wires connected to three terminal screws plus a
green or bare wire connected to a green terminal screw. The three terminals are
usually one dark colored screw and two light colored screws (ignore the Green
screw). Alternatively, the three screws may be the same color and one will be
marked COMMON or COM Find the wires connected to the dark or COMMON
screws. Usually these wires are black but may be red or blue. Tag these wires on
both switches
to identify when wiring.
Three location:
Two of the existing switches will be 3-way. The 3-way switches will be located
at each end of the circuit with a 4-way switch in between. TAG the two 3-way
switches as in the Two Location Control section. The 4-Way switch has 4 insu-
lated wires connected to 4 terminal screws.
VERY IMPORTANT - TAG two same
color insulated wires, which are connected to screws of opposite colors.
Refer to 1.4 to push dimmers into place.
Black
White
Black
Bare
1.1
1.2
Master
Black
Black
Green
Red
Black
White
White
1.3
TOP
1.4
Black
Bare
Black
Red
Tag
White
2.1
Black
Bare
Black
Red
Tag
White
2.2
Green
Red
Tag
Black
Accessory
ACCESSORY
White
Black
LOCATION A
ACCESSORY
White
2.3
Master
Red
Green
White
Black
Black
Tag
Black
Red
MASTER
DIMMER
White
2.4
White
Black
Red
Red
Bare
Tag
Black
Tag
3.1
Accessory
White
Red
Black
Black
Green
ACCESSORY
White
Tag
4-Way Location
3.2
Tag
-
To Light
Tag
- Hot
Red
Black
Hot
Neutral
120V
Light Fixture
Green
Ground
Green
Ground
White
White
White
ACCESSORY
DIMMER
Red
White
Black
Traveler Wires
Green
Ground
White
White
White
Black
Red
Black
Traveler Wires
LOCATION A
ACCESSORY
DIMMER
MASTER
DIMMER
RFAL-DIMR-U-EN (REV. A)
Universal Remote Control, Inc.
500 Mamaroneck Ave.
Harrison, NY 10528
(914) 835-4484
www.UniversalRemote.com