Use only the air

Page 58 highlights

Maintenance Air filter Please check and clean the air filter periodically. When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. Replace the air filter when it is damaged or too soiled. To prepare a new air filter, contact your dealer and tell the air filter type number. When you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector. Cleaning the air filter 1. Turn the projector off, and unplug the power cord. Allow the projector to sufficiently cool down. 2. Use a vacuum cleaner on and around the filter cover. 3. Pull the filter cover knobs while lifting it. The filter unit which consists of the filter' cover, air filter and filter frame will come off. 4. Use a vacuum cleaner for the filter vent of the projector and the filter frame side of the filter unit. If the air filter is damaged or too soiled, replace it according to the following procedure number 5 to 7. Otherwise, please jump to the procedure number 8. 5. Pull the filter frame' knob up while holding the filter cover. The filter frame will come off and the air filter will appear. 6. Replace the air filter with new one. Filter cover Filter cover knobs Filter unit Filter frame Air filter 7. Put the filter frame back. 8. Put the filter unit back into the projector. 9. Turn the projector on and reset the filter time using the FILTER TIME item in the EASY MENU. Filter cover (1) Press the MENU button to display a menu. (2) Point at the "FILTER TIME" using the ▼/▲ button, then press the ► button. A dialog will appear. (3) Press the ▲ button to select "RESET" on the dialog. It performs resetting the filter time. WARNING ►Before taking care of the air filter, make sure the power cable is not plugged in, then allow the projector to cool sufficiently. ►Use only the air filter of the specified type. Do not use the projector without the air filter or the filter cover. It could result in a fire or malfunction to the projector. ►Clean the air filter periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn or malfunction to the projector. NOTE • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter. • The projector may display the message such as "CHECK THE AIR FLOW" or turn off the projector, to prevent the internal heat level rising. ViewSonic 53 PJ758/PJ759/PJ760

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

ViewSonic
53
PJ758/PJ759/PJ760
Please check and clean the air
lter periodically. When the indicators or a
message prompts you to clean the air
lter, comply with it as soon as possible.
Replace the air
lter when it is damaged or too soiled. To prepare a new air
lter,
contact your dealer and tell the air
lter type number.
When you replace the lamp, please replace the air
lter. An air
lter of speci
ed
type will come together with a replacement lamp for this projector.
Cleaning the air
lter
1.
Turn the projector off, and unplug the power cord.
Allow the projector to suf
ciently cool down.
2.
Use a vacuum cleaner on and around the
lter
cover.
3.
Pull the
lter cover knobs while lifting it. The
lter
unit which consists of the
lter’ cover, air
lter and
lter frame will come off.
4.
Use a vacuum cleaner for the
lter vent of the
projector and the
lter frame side of the
lter unit.
If the air
lter is damaged or too soiled, replace it
according to the following procedure number 5 to 7.
Otherwise, please jump to the procedure number 8.
5.
Pull the
lter frame’ knob up while holding the
lter
cover. The
lter frame will come off and the air
lter will appear.
6.
Replace the air
lter with new one.
7.
Put the
lter frame back.
8.
Put the
lter unit back into the projector.
9.
Turn the projector on and reset the
lter time using
the FILTER TIME item in the EASY MENU.
(1) Press the MENU button to display a menu.
(2)
Point at the “FILTER TIME” using the
/
button, then press the
button. A dialog will appear.
(3) Press the
button to select “RESET” on the dialog. It performs resetting the
lter time.
Maintenance
Air
lter
NOTE
• Please reset the
lter time only when you have cleaned or
replaced the air
lter, for a suitable indication about the air
lter.
• The projector may display the message such as “CHECK THE AIR FLOW”
or turn off the projector, to prevent the internal heat level rising.
WARNING
Before taking care of the air
lter, make sure the power cable
is not plugged in, then allow the projector to cool suf
ciently.
Use only the air
lter of the speci
ed type. Do not use the projector without the
air
lter or the
lter cover. It could result in a
re or malfunction to the projector
.
Clean the air
lter periodically. If the air
lter becomes clogged by dust or the like,
internal temperatures rise and could cause a
re, a burn or malfunction to the projector.
Filter cover
Filter cover knobs
Filter unit
Filter cover
Filter frame
Air
lter