ViewSonic VA702B Service Manual - Page 36
Do Auto Image Adjust
UPC - 766907146417
View all ViewSonic VA702B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Y measurement at default setting Panel Flicker check Power saving 1. Set brightness to default value 100 and contrast to default value 70 at 6500K 2. At full white patter, Measure Y, which should be 250+/-10cd/m² (QDI 220+/- 10cd/m²) 1. Mode: 1280x1024@60Hz 2. Set Brightness& contrast to default value 3. Do "Auto Image Adjust" 4. Shut down PC to check whether there's glitter on the center of the picture. 1. Mode: 1280x1024@60Hz 2. Pattern: full white 3. Brightness: Max. 4. Contrast: Default 5. Check power consumption at each modes State Power Consumption LED color Normal <38W Green Stand By <1W Orange Power Key Off <1W No Chroma Signal Generator and Color Analyzer Equipment:: Chroma Signal Generator & PC Chroma signal generator and Power meter AC input: 230V/50Hz ViewSonic Corporation Confidential - Do Not Copy 33 VA702-1_VA702b-1