ViewSonic VTMS2431 User Guide - Page 56
Send Hex Format
UPC - 766907342017
View all ViewSonic VTMS2431 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
ENGLISH Other Information If the Command is Not valid, Command Type= "-", Only for HDTV power status on standby. Name Byte Count Bytes order Length 1 Byte 1 Command Type 1 Byte 2 CR 1 Byte 3 Example1: Get power status on standby and this command is valid. Send (Hex Format) Name Length Command Command Value1 Value2 Value3 CR Type Hex 0x36 0x67 0x6C 0x30 0x30 0x30 0x0D Reply (Hex Format) Name Length Command Command Value1 Value2 Value3 CR Type Hex 0x36 0x72 0x6C 0x30 0x30 0x30 0x0D Example2: Get Brightness from TV-05 and this command is valid. The Brightness value is 67. Send (Hex Format) Name Length ID Command Command Value1 Value2 Value3 CR Type Hex 0x38 0x30 0x67 0x62 0x30 0x30 0x30 0x0D 0x35 Reply (Hex Format) Name Length ID Hex 0x38 0x30 0x35 Command Command Type 0x72 0x62 Value1 0x30 Value2 0x36 Value3 0x37 CR 0x0D Example3: Get Brightness from TV-05 , but the Brightness command ID is error and it is NOT in the command table. Send (Hex Format) Name Length ID Command Command Value1 Value2 Value3 CR Type Hex 0x38 0x30 0x67 0xD3 0x30 0x30 0x30 0x0D 0x35 Reply (Hex Format) Name Length ID Command CR Type Hex 0x34 0x30 0x2D 0x0D 0x35 Contact ViewSonic service team at: http://www.ViewSonic.com or call our service team: United States 1-800-688-6688, Canada 1-866-463-4775 ViewSonic 51 VTMS2431