Viking DGRT3014BBK Installation Instructions - Page 4

Proximity to Side Cabinet Installation, GENERAL INFORMATION, GAS INLET/ELECTRICAL LOCATION - appliances

Page 4 highlights

GENERAL INFORMATION 1. WARNING: The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets. 2. All openings in the wall behind the appliance and in the floor under the appliance shall be sealed. 3. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors. 4. Do not obstruct the flow of combustion and ventilation air. 5. Disconnect the electrical supply to the appliance before servicing. 6. When removing oven for cleaning and/or service; A. Shut off gas at main supply B. Disconnect AC power supply C. Disconnect gas line to the inlet pipe. D. Carefully remove the rangetop by pulling out of cabinet cutout. E. When cleaning and/or service is complete, replace unit in cabinet cutout, reconnect gas line and power sup- ply, and turn on gas at main supply. 7. Electrical Requirement Listed on Specification sheet. Electrical installation should comply with national and local codes. 8. Gas Manifold Pressure: Natural gas - 5.0" W.C.P. LP/Propane - 10.0" W.C.P. WARNING Never use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisioning and over heating of the unit. GAS INLET/ELECTRICAL LOCATION A B 3/4" Min. (1.9 cm) 120 VAC/60 Hz within 48" (121.9 cm) of right rear of rangetop VGRT Models 24", 30", 36", 42",48" W. VGRT Models 60" W. DGRT Models 30", 36" W. A Min. 24" (61.0 cm) Max. 25 3/4 (65.4 cm) Min. 24" (61.0 cm) Max. 25 3/4 (65.4 cm) Min. 24 1/2" (62.2 cm) Max. 26 1/8" (66.4 cm) B 3" (7.6 cm) 14 3/8" (36.5 cm) 3" (7.6 cm) C 2 1/4" (5.7 cm) 9/16" (1.8 cm) 2 1/4" (5.7 cm) 5 Proximity to Side Cabinet Installation 1. This rangetop may be installed directly adjacent to existing 36" (91.4 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertop. 2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36" (91.4 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36" (91.4 cm) counter height. 3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm) , the maximum wall cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm) above the 36" (91.4 cm) high countertop. 4. Wall cabinets above the rangetop must be a minimum of 36" (91.4 cm) for the open top burner models and a minimum of 42" (106.7 cm) for the sealed burner models above the rangetop cooking surface for the full width of the rangetop. This minimum height requirement does not apply if a rangehood is installed over the cooking surface. Dim. 24" W. Models A 24" (61.0 cm) 30" W. Models 30" (76.2 cm) 36" W. Models 36" (91.4 cm) 42" W. Models 48" W. Models 60" W. Models 42 1/8" (107.0 cm) 48" (121.9 cm) 59 5/8" (151.4 cm) Dim. VGRT Open Burners VGRT Sealed Burners DGRT Sealed Burners B 36" (91.4 cm) min. 42" (106.7 cm) min. 42" (106.7 cm) min. C 7 1/2" (19.1 cm) 7 5/8" (19.4 cm) 5 3/4" (14.6 cm) B A C 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Proximity to Side Cabinet Installation
1. This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.
IMPORTANT:
The top
grate support MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop.
2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical
surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the rangetop to
such combustible surfaces above the 36” (91.4 cm) counter height.
3. Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm) , the maximum wall cabi-
net depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm)
above the 36” (91.4 cm) high countertop.
4. Wall cabinets above the rangetop must be a minimum of 36” (91.4 cm) for the open top burner models and a mini-
mum of 42” (106.7 cm) for the sealed burner models above the rangetop cooking surface for the full width of the
rangetop. This minimum height requirement does not
apply if a rangehood is installed over the cooking surface.
Dim. 24” W. Models
30” W. Models
36” W. Models
42” W. Models
48” W. Models
60” W. Models
A
24” (61.0 cm)
30” (76.2 cm)
36” (91.4 cm)
42 1/8” (107.0 cm)
48” (121.9 cm)
59 5/8” (151.4 cm)
B
A
C
Dim.
B
C
VGRT Open Burners
36” (91.4 cm) min.
7 1/2” (19.1 cm)
VGRT Sealed Burners
42” (106.7 cm) min.
7 5/8” (19.4 cm)
DGRT Sealed Burners
42” (106.7 cm) min.
5 3/4” (14.6 cm)
6
5
GENERAL INFORMATION
1.
WARNING
:
The use of cabinets for storage above the appliance may result in a potential burn hazard. Com-
bustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided
the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm) beyond the
bottom of the cabinets.
2. All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.
3. Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
4. Do not obstruct the flow of combustion and ventilation air.
5. Disconnect the electrical supply to the appliance before servicing.
6. When removing oven for cleaning and/or service;
A. Shut off gas at main supply
B. Disconnect AC power supply
C. Disconnect gas line to the inlet pipe.
D. Carefully remove the rangetop by pulling out of cabinet cutout.
E. When cleaning and/or service is complete, replace unit in cabinet cutout, reconnect gas line and power sup-
ply, and turn on gas at main supply.
7.
Electrical Requirement
Listed on Specification sheet. Electrical installation should comply with national and local codes.
8.
Gas Manifold Pressure:
Natural gas - 5.0” W.C.P.
LP/Propane - 10.0” W.C.P.
GAS INLET/ELECTRICAL LOCATION
A
B
C
VGRT Models -
Min. 24” (61.0 cm)
3” (7.6 cm)
2 1/4” (5.7 cm)
24”, 30”, 36”, 42”,48” W.
Max. 25 3/4 (65.4 cm)
VGRT Models -
Min. 24” (61.0 cm)
14 3/8” (36.5 cm)
9/16” (1.8 cm)
60” W.
Max. 25 3/4 (65.4 cm)
DGRT Models -
Min. 24 1/2” (62.2 cm)
3” (7.6 cm)
2 1/4” (5.7 cm)
30”, 36” W.
Max. 26 1/8” (66.4 cm)
B
3/4” Min.
(1.9 cm)
A
WARNING
Never use this appliance as a space heater to heat or
warm the room. Doing so may result in carbon monox-
ide poisioning and over heating of the unit.
120 VAC/60 Hz within
48” (121.9 cm) of right
rear of rangetop