Viking DMOR200SS Installation Instructions - Page 4

Preparation of the Oven, Ventilation System - designer

Page 4 highlights

7 Preparation of the Oven Separate mounting plate from oven by removing two screws. See illustration below. Save these screws for use in section Mounting Oven to Wall, figure /. (B) Horizontal Exhaust: Outside Ventilation 4 5 Mounting Plate figure figure Back of Microwave 1) HORIZONTAL EXHAUST: Remove 2 screws from back edge and 3 screws from the top center of Fan Cover Bracket. Save 2 screws to be used later and discard remaining 3. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket. figure 6 8 Ventilation System (Preparing Oven for Installation) Hood Fan Unit This Built-in Microwave Hood is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation. RECIRCULATING - non-vented, ductless. Follow installation procedure (A). Recirculating requires the use of the Charcoal Filter, which has already been installed in the oven. HORIZONTAL EXHAUST - outside ventilation. Follow installation procedure (B). VERTICAL EXHAUST - outside ventilation. Follow installation procedure (C). 2) HORIZONTAL EXHAUST: Lift Hood Fan Unit carefully and slip wires out of cavity. • CAUTION: Do not pull or stretch hood fan wiring. 7 (A) Rotate 180˚ (B) figure (A) Recirculating: Non-Vented, Ductless Operation • The unit is shipped assembled for recirculating. • The Exhaust Damper Assembly 7 is NOT REQUIRED for recirculating operation. 3) HORIZONTAL EXHAUST: Rotate the Hood Fan Unit 180˚ so that the fan blade openings are facing the back of the oven. See Figure 7 (A). Replace Hood Fan Unit into the oven. Be careful not to pinch the wire and the Hood Fan Unit. See Figure 7 (B). E4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

E4
7 Preparation of the Oven
Separate mounting plate from oven by removing two
screws. See illustration below. Save these screws for use
in section
Mounting Oven to Wall
, figure
/
.
Mounting
Plate
Back of Microwave
figure
figure
4
8 Ventilation System
(Preparing
Oven for Installation)
This Built-in Microwave Hood is designed for adaptation
to three types of hood ventilation systems. Select the
type required for your installation.
RECIRCULATING
— non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has already been
installed in the oven.
HORIZONTAL EXHAUST
— outside ventilation.
Follow installation procedure (B).
VERTICAL EXHAUST
— outside ventilation.
Follow installation procedure (C).
(A) Recirculating:
Non-Vented, Ductless
Operation
• The unit is shipped assembled for recirculating.
• The Exhaust Damper Assembly
7
is NOT REQUIRED
for recirculating operation.
(B) Horizontal Exhaust:
Outside
Ventilation
figure
figure
5
1) HORIZONTAL EXHAUST:
Remove 2 screws from back
edge and 3 screws from the top center of Fan Cover Bracket.
Save 2 screws to be used later and discard remaining 3.
Remove Fan Cover Bracket by sliding it in the opposite
direction of the arrow on the Fan Cover Bracket.
figure
figure
6
Hood Fan Unit
2) HORIZONTAL EXHAUST:
Lift Hood Fan Unit carefully
and slip wires out of cavity.
• CAUTION:
Do not pull or stretch hood fan wiring.
figure
figure
7
(A) Rotate 180˚
(B)
3) HORIZONTAL EXHAUST:
Rotate the Hood Fan Unit 180˚
so that the fan blade openings are facing the back of the
oven. See Figure
7
(A). Replace Hood Fan Unit into the
oven. Be careful not to pinch the wire and the Hood Fan
Unit. See Figure
7