Charcoal Filter Charcoal Filter is used for Non-vented, recirculated installation. The filter should be changed every 6 to 12 months depending on use. 1. Disconnect power to the oven at the circuit breaker panel or by unplugging. 2. Remove 2 screws that secure louver. 3. Remove louver by gently moving louver and pull away from unit. 4. Remove 2 screws that secure the sensor duct cover. 5. Remove the sensor duct cover. 6. Remove old charcoal filter (if one is installed). 7. Slide new charcoal filter into position on the support tabs. 8. Reattach sensor duct cover and secure with 2 screws. 9. Push louver back into place and replace the 2 screws to secure louver. Sensor duct cover Charcoal filter E41
![](/manual_guide/products/viking-rdmor206ss-use-care-manual-b7dc97d/43.png)
E41
CHARCOAL FILTER
Charcoal Filter is used for Non-vented, recirculated installation. The filter should
be changed every 6 to 12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or by unplugging.
2. Remove 2 screws that secure louver.
3. Remove louver by gently moving louver and pull away from unit.
4. Remove 2 screws that secure the sensor duct cover.
5. Remove the sensor duct cover.
6. Remove old charcoal filter (if one is installed).
7. Slide new charcoal filter into position on the support tabs.
8. Reattach sensor duct cover and secure with 2 screws.
9. Push louver back into place and replace the 2 screws to secure louver.
Sensor duct cover
Charcoal filter