Viking VCBB5363ER Installation Instructions - Page 22
Water Filter System Specification and Performance Data, Sheet
View all Viking VCBB5363ER manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Water Filter System Specification and Performance Data Sheet This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.) Contaminant Reduction Average Influent NSF Specified Challenge Concentration Avg % Reduction Average Product Water Concentration Max Permissible NSF Product Water Reduction Concentration Requirements NSF Test Report Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L + 10% Nominal Particulate 13,666,667 Class I, >0.5 to < pts/mL 1.0 µm At least 10,000 particles/mL Asbestos 96 MF/L 107 to 108 fibers/L; fibers greater than 10µm in length Atrazine 0.010 mg/L 0.009 mg/L + 10% Cyst* 122,500 cysts/L Minimum 50,000 cysts/L Lead @ pH 6.5 0.153 mg/L 0.15 mg/L + 10% Lead @ pH 8.5 0.150 mg/L 0.15 mg/L + 10% Lindane 0.002 mg/L 0.002 mg/L + 10% Mercury @ pH 6.5 0.006 mg/L 0.006 mg/L + 10% Mercury @ pH 8.5 0.006 mg/L 0.006 mg/L + 10% Toxaphene 0.015 mg/L 0.015 mg/L + 10% Turbidity 10.8 NTU 11 + 1 NTU 97.5% 98.9% >99% 89.3% 99.99% 99.3% 99.3% 97.8% 95.0% 88% 93.2% 98.7% 0.05 mg/L 143,333 pts/mL 50% > 85% J-00056501 J-00056506 > 99% J-00056511 N/A > 99.95% J-00056512 J-00056513 N/A J-00056515 N/A J-00058784 N/A J-00058969 N/A J-00058785 N/A J-00058783 N/A J-00056531 N/A J-00058972 *Based on the use of Cryptosporidium parvum oocysts Operating Specifications Capacity: Certified for up to 750 gallons (2,838 L); up to nine months Pressure Requirement: 20 - 120 psi (1.4 - 8.2 bar) Temperature: 33-100º F (0.6 - 37.8º C) Flow rate: 0.78 gpm (2.9 l/min.) Check for compliance with the state and local laws and regulations. Note: While the testing was performed under standard laboratory conditions, actual performance may vary. Must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer's instruction, including replacement of filter cartridges. Manufactured by: 3M Purification Inc. System tested and certified by NSF International 400 Research Parkway against Standard 42 for the reduction of chlorine Meriden, CT 06770 taste and odor, particulate Class I and Standard 53 for the reduction of Lead, Lindane, Atrazine, Mercury, Toxaphene, Cyst, Turbidity, and Asbestos. 22