Viking VCWB300RSS Installation Instructions - Page 2
Warning, Danger - warranty
View all Viking VCWB300RSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
IMPORTANT - PLEASE READ AND FOLLOW Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product. To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction. The installer should leave these instructions with the consumer who should retain them for local inspector's use and for future reference. GENERAL INFORMATION Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word "DANGER" or "WARNING". These words mean: WARNING TIP OVER HAZARD Wine cellar is top heavy and tips easily when not completely installed. DANGER You will be killed or seriously injured if you don't follow instructions. Keep door closed and shelves in place until wine cellar is completely installed per installation instructions. WARNING You can be killed or seriously injured if you don't follow instructions. Use two or more people to move and install wine cellar. Failure to do so can result in death or serious injury. Most of the wine cellar's weight is at the top. Extra care is needed when moving the wine cellar to prevent tipping. Use cardboard shipping material or plywood under wine cellar until it is installed in the operating position to protect floor surface. It is your responsibility to: -comply with installation specifications and dimensions -properly install wine cellar -remove any moldings or decorative panels that prevent the wine cellar from being serviced -assure that floor will support wine cellar, door panels and contents (approximately 1200 lbs. [540 kg]). -provide a properly grounded electrical outlet -assure that location will permit appliance doors to open 90° minimum All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. • The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. If the use of a GFI is required, it should be: • Of the receptacle type (breaker type or portable type NOT recommended) • Used with permanent wiring only (temporary or portable wiring NOT recommended) • On a dedicated circuit (no other receptacles, switches or loads in the circuit) • Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended) • Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard • In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations) • Protected from moisture (water, steam, high humidity) as much as reasonably possible 2 BASIC SPECIFICATIONS AND DIMENSIONS DESCRIPTION Overall Width Overall Height from Bottom Overall Depth from Rear Cutout Width Cutout Height Cutout Depth Electrical Requirements Maximum Amp Usage Overall Capacity Approximate Shipping Weight VCWB300 30" (76.2 cm) Min. 82-3/4" (210.2 cm) to Max. 84-1/16" (213.5 cm) To rear edge of side trim To front of top grille To end of handle bracket 22-3/16" (56.4 cm) 24-1/2" (62.2 cm) 27" (68.6 cm) 29-1/2" (74.9 cm) 82-7/8" (210.5 cm) min.; 84-1/16" (213.5 cm) max. 24" (61.0 cm) min. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product. 2.3 amps 150 bottles 560 lbs. (252 kg) DESCRIPTION Overall Width Overall Height from Bottom Overall Depth from Rear To front edge of side trim To front edge of cabinet side trim To front edge of door handle Cutout Width Cutout Height Cutout Depth Electrical Requirements Maximum Amp Usage Overall Capacity Approximate Shipping Weight DDWB301 DFWB300 30" (76.2 cm) Min. 82-3/4" (210.2 cm) to Max. 84-1/16" (213.5 cm) 23-13/16" (60.5 cm) 24" (61.0 cm) 26-1/2" (67.3 cm) 23-13/16" (60.5 cm) 24-3/4" (62.9 cm) 24" (61.0 cm) 30" (76.2 cm) 82-7/8" (210.5 cm) min.; 84-1/16" (213.5 cm) max. 24" (61.0 cm) min. 25" (63.5 cm) - can be installed in 24" (61.0 cm) deep openings; door faces and top grille will protrude 3/4" (1.9 cm) into room. 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product. 2.3 amps 150 bottles 560 lbs. (252 kg) 3