Electrical Requirements WARNING ELECTRICAL GROUNDING INSTRUCTIONS This cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the National Electrical Code, ANSI/NFPA 70latest edition. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Electrical Requirements Check your local codes regarding this unit. This cooktop is supplied with a 3-wire, A.C. 208V/120 volt or 120V/240 volt, 60 HZ electrical system. A white (neutral) is not needed for this unit. See next section for grounding instructions. It should be fused separately. CAUTION Be sure the electric power is off from the breaker box to the junction box until the cooktop is installed and ready to operate. The junction box should be connected to a suitable ground. Refer to the specifications chart for kilowatt rating and recommended amperage. House wiring and fusing must comply with local codes. If no local codes are applicable, wire in accordance with the National Electrical Code, ANSI/NFPA 70-latest edition. WARNING The electrical power to the unit must be shut off while line connections are being made. Failure to do so could result in serious injury or death. Electrical Connection When making the wire connections, use the entire length of the conduit provided (3 feet). The conduit must not be cut. Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit is connected to the unit frame. When connecting to a 3-conductor branch circuit, connect the bare ground connector lead of the unit to the branch circuit ground (bare wire or green in color). WARNING FIRE AND ELECTRICAL SHOCK HAZARD DO NOT use an extension cord with this appliance. Such use may result in fire, electrical shock, or other personal injury. 12 General Information READ AND FOLLOW ALL WARNING AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE. • Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors. • Disconnect the electrical supply prior to servicing or cleaning. Installation • When removing the cooktop for service and/or cleaning, disconnect AC power supply. • Electrical requirements are listed in the product specifications under the "Electrical Requirements" section. 1 2 Ground Green Red Black Lower cooktop into cutout. 3 Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. 4 Countertop Cooktop Bracket Screw brackets to burner box with sheet metal screw. (Two bracket assemblies included) Screw sheet metal screws into brackets and tighten firmly against bottom of countertop. Note: Be careful not to crack or damage counter by overtightening. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

12
Electrical Requirements
Check your local codes regarding this unit.
This cooktop is supplied with a 3-wire, A.C.
208V/120 volt or 120V/240 volt, 60 HZ
electrical system. A white (neutral) is not
needed for this unit. See next section for
grounding instructions. It should be fused
separately.
Refer to the specifications chart for kilowatt
rating and recommended amperage. House
wiring and fusing must comply with local
codes. If no local codes are applicable, wire
in accordance with the National Electrical
Code, ANSI/NFPA 70-latest edition.
Electrical Connection
When making the wire connections, use
the entire length of the conduit provided
(3 feet). The conduit must not be cut.
Connect the red and black leads from the
unit conduit to the corresponding leads in
the junction box. The bare ground wire in the
conduit is connected to the unit frame. When
connecting to a 3-conductor branch circuit,
connect the bare ground connector lead of
the unit to the branch circuit ground (bare
wire or green in color).
WARNING
ELECTRICAL
GROUNDING
INSTRUCTIONS
This cooktop must be electrically
grounded in accordance with local codes
or, in the absence of codes, with the
National Electrical Code, ANSI/NFPA 70-
latest edition.
FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
CAUTION
Be sure the electric power is
off from the breaker box to the
junction box until the cooktop
is installed and ready to
operate. The junction box should be
connected to a suitable ground.
WARNING
The electrical power to the
unit must be shut off while line
connections are being made.
Failure to do so could result
in serious injury or death.
WARNING
FIRE AND ELECTRICAL
SHOCK HAZARD
DO NOT
use an extension
cord with this appliance. Such
use may result in fire, electrical
shock, or other personal injury.
13
READ AND FOLLOW ALL WARNING
AND CAUTION INFORMATION
WHEN INSTALLING THIS APPLIANCE.
• Keep appliance area clear and free from
combustible materials, gasoline and other
flammable vapors.
• Disconnect the electrical supply prior to
servicing or cleaning.
• When removing the cooktop for service
and/or cleaning, disconnect AC power
supply.
• Electrical requirements are listed in the
product specifications under the “Electrical
Requirements” section.
Installation
1
2
Ground
Green
Black
Red
Lower cooktop into cutout.
Connect the red and black leads from the unit conduit
to the corresponding leads in the junction box.
Cooktop
Bracket
Countertop
3
4
Screw brackets to burner box with sheet metal screw.
(Two bracket assemblies included)
Screw sheet metal screws into brackets
and tighten firmly against bottom of countertop.
Note:
Be careful not to crack or damage
counter by overtightening.
Electrical Requirements