OUTDOOR-COOKING Built-In Gas Side Burner, 24"W. Rangetop, Wok/Cooker, & TruSear™ Infrared Grillers Dimensions & Specifications CUTOUT DIMENSIONS (913.16"cm) (156.2"cmmi)n. (1206-.01/c4m") (12.57"cm) Gas inlet pipe location (12.7 5" cm) 27(6-19/.92"cm) (351.64"cm) (156.2"cmmi)n. (1206-.01/c4m") (12.7 5" cm) (913.16"cm) (2642-.93/c4m") Gas inlet pipe location (512".72cm7(6-)19/.92"cm) VGSB152T/VGIB151T VGRT244T/VGWT241T/VGIB242T 15"W. SIDEBURNERS & GRILLERS 1. Maintain a minimum of 6" (15.2 cm) from the sides of the side burners (above the cooking surface) to adjacent vertical combustible construction. Do not install under overhead, unprotected combustible construction. 2. Allow at least 6" side clearance to non-combustible construction above the cooking surface for counter space. 3. When choosing a suitable location, consider factors such as wind exposure, proximity to traffic paths, keeping gas supply lines as short as possible. Install only in a wellventilated area. Never install in a building, garage, breezeway, shed, or other such fully enclosed areas. 24"W. RANGETOP/WOK/GRILLER PROXIMITY TO CABINET INSTALLATION The unit may be installed directly adjacent to the existing base cabinets. The side trim must be 3/8" (0.95 cm) above the adjacent base cabinet countertop. There is a 0" side and rear clearance to non-combustible surfaces. The unit cannot be installed directly adjacent to combustible sidewalls. There must be a minimum of 6" (15.2 cm) side and rear clearance from the unit to such combustible surfaces. This unit cannot be placed under an overhead which is unprotected and combustible. Cutout width Cutout height Cutout depth VGSB152T 14" (35.6 cm) 27-1/2" (69.9 cm) VGRT244T 24-3/4" (62.9 cm) 27-1/2" (69.9 cm) VGWT241T 24-3/4" (62.9 cm) 10-1/4" (26.0 cm) 27-3/8"(69.5 cm) min. to 27-7/8" (70.8 cm) max. VGIB151T 14" (35.6 cm) 27-1/2" (69.9 cm) VGIB242T 24-3/4" (62.9 cm) 27-1/2" (69.9 cm) PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 RELEASED 12/1/07 © 2 0 0 7 V R C - INFORMATION SUBJECT TO CHANGE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

36”
(91.1 cm)
10-1/4”
(26.0 cm)
14”
(35.6 cm)
5”
(12.7 cm)
5”
(12.7 cm)
6” min.
(15.2 cm)
27-1/2”
(69.9 cm)
Gas inlet
pipe location
36”
(91.1 cm)
10-1/4”
(26.0 cm)
24-3/4”
(62.9 cm)
5”
(12.7 cm)
6” min.
(15.2 cm)
27-1/2”
(69.9 cm)
5”
(12.7 cm)
Gas inlet
pipe location
OUTDOOR—COOKING
Built-In Gas Side Burner, 24”W. Rangetop,
Wok/Cooker, & TruSear
Infrared Grillers
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM
1-888-VIKING1
RELEASED 12/1/07
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
Dimensions & Specifications
CUTOUT DIMENSIONS
VGSB152T/VGIB151T
VGRT244T/VGWT241T/VGIB242T
VGSB152T
VGRT244T
VGWT241T
VGIB151T
VGIB242T
Cutout width
14” (35.6 cm)
24-3/4” (62.9 cm)
24-3/4” (62.9 cm)
14” (35.6 cm)
24-3/4” (62.9 cm)
Cutout height
10-1/4” (26.0 cm)
Cutout depth
27-1/2” (69.9 cm)
27-1/2” (69.9 cm)
27-3/8”(69.5 cm) min. to
27-1/2” (69.9 cm)
27-1/2” (69.9 cm)
27-7/8” (70.8 cm) max.
15”W. SIDEBURNERS & GRILLERS
1. Maintain a minimum of 6” (15.2 cm)
from the sides of the side burners
(above the cooking surface) to
adjacent vertical combustible
construction. Do not install under
overhead, unprotected combustible
construction.
2. Allow at least 6” side clearance to
non-combustible construction above
the cooking surface for counter space.
3. When choosing a suitable location,
consider factors such as wind
exposure, proximity to traffic paths,
keeping gas supply lines as short as
possible. Install only in a well-
ventilated area. Never install in a
building, garage, breezeway, shed, or
other such fully enclosed areas.
24”W. RANGETOP/WOK/GRILLER
PROXIMITY TO CABINET INSTALLATION
The unit may be installed directly
adjacent to the existing base cabinets.
The side trim must be 3/8” (0.95 cm)
above the adjacent base cabinet
countertop. There is a 0” side and rear
clearance to non-combustible surfaces.
The unit cannot be installed directly
adjacent to combustible sidewalls. There
must be a minimum of 6” (15.2 cm) side
and rear clearance from the unit to such
combustible surfaces. This unit cannot be
placed under an overhead which is
unprotected and combustible.