Viking VGSB152TNSS Specs - Page 6
OUTDOOR-COOKING, Installation Requirements
View all Viking VGSB152TNSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
OUTDOOR-COOKING Built-In Gas Side Burner, 24"W. Rangetop, Wok/Cooker, & TruSear™ Infrared Grillers Installation Requirements VGSB152T Double Side Burner VGRT244T 24"W. Rangetop GAS Burner rating • VGSB152T-Two grated burners @ 15,000 BTU (4.4 kW) Nat./13,500 BTU LP (4.0 kW) • VGRT244T-Four grated burners @ 15,000 BTU (4.4 kW) Nat./13,500 BTU LP (4.0 kW) • VGWT241T-One grated burner @ 27,500 BTU (8.1 kW) Nat./LP • VGIB151T-One infrared grill burner @ 21,500 BTU (6.3 kW) Nat./20,000 BTU (5.9 kW) LP • VGIB242T-Two infrared grill burners, each @ 21,500 BTU (6.3 kW) Nat./20,000 BTU (5.9 kW) LP • Fixed piping installations o Check with local gas utility company or with local codes for instructions on installing gas supply lines. All gas connections should be made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1. o An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer-supplied parts must conform to local codes. o Must be isolated from the gas supply piping system by closing its individual manual VGWT241T 24"W. Wok/Cooker VGIB151T 15"W. TruSear Infrared Griller VGIB242T 24"W. TruSear Infrared Griller UTILITY REQUIREMENTS shut-off valve during any pressure testing of that system at test pressures equal to or less than 1/2 psi (3.5 kPa). • Natural gas models (and LP/propane, for VGWT only) o Water column pressure • Operating pressure-4.0" WCP • Supply pressure of 6" - 14" WCP • If incoming pressure exceeds 14" WCP, a stepdown regulator is required. o Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 7/8" (2.2 cm) flare adapter. o If using a Viking GSH12 flexible hose, remove the 1/2" (1.3 cm) flare adapter and attach hose to the 7/8" (2.2 cm) male flare on the regulator assembly. • LP/propane models o Water column pressure • Operating pressure-10" WCP • Supply pressure of 11" - 14" WCP (for fixed piping installations) • If incoming pressure exceeds 14" WCP, a stepdown regulator is required. o Accepts standard residential 1/2" (1.3 cm) ID gas service line; 1/2" (1.3 cm) NPT male with 3/8" (0.95) flare adapter. • LP/propane tank installations o Water column pressure • Operating pressure-10" WCP o Includes high-capacity hose/regulator assembly for connection to a standard 5- gal./20-lb. (approx. 12" diameter/18"H.) LP/propane gas cylinder equipped with a Type 1, QCC-1 connector • The cylinder connection device must be compatible with the Type 1, QCC-1 connector on the outdoor cooking appliance. • The cylinder must be provided with a shut- off valve terminating in an LP/propane gas supply cylinder valve outlet specified. • The cylinder supply system must be arranged for vapor withdrawal and provided with a listed OPD (overfilling prevention device). ELECTRICAL • 9-volt DC battery for electronic ignition (not included?) • Max. amp usage o VGWT-0.08 PLUMBING Not applicable PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 RELEASED 12/1/07 © 2 0 0 7 V R C - INFORMATION SUBJECT TO CHANGE