Viking VGSU5366BSS Natural Gas Conversion Kit - NATVGC - Installation Instruct - Page 3

VGC/CVGC Orifice Locations - manual

Page 3 highlights

VGC/CVGC Orifice Locations VGC/CVGC530 VGSU/CVGSU530 Burner NAT Left Front (A) Left Rear (B) Center (B) .079 (2.01mm) 044706-000 .064 (1.63 mm) PB040255 .064 (1.63 mm) PB040255 Right Rear (C) .051 (1.30 mm) 044707-000 Right Front (D) .042 (1.07 mm) PB040274 B B C VGC/CVGC536 VGSU/CVGSU536 Burner NAT Left Front (A) .079 (2.01mm) 044706-000 Left Rear (B .056 (1.42 mm) 044708-000 Center Rear (C) .060 (1.52 mm) PB040255 Center Front (C) .060 (1.52 mm) PB040255 Right Rear (E) .048 (1.22 mm) 044709-000 Right Front (D) .042 (1.07 mm) PB040274 B C E A D A C D Burner 30"W. Model Burner 36"W. Model Left Front (A) Left Rear (B) Center (B) 18,000 BTU NAT (5.4 kW NAT) 12,000 BTU NAT (3.6 kW NAT) 12,000 BTU NAT (3.6 kW NAT) Left Front (A) Left Rear (B) Center Rear (C Center Front (C) Right Rear (C) Right Front (D) 8,000 NAT (2.4 kW NAT) 6,000 BTU NAT (1.8 kW NAT) Right Rear (E Right Front (D) *Burner rates will be lowered by 4% per 1000 ft. above altitudes of 2000 ft. 18,000 BTU NAT (5.4 kW NAT) 10,000 BTU NAT (3.0 kW LP) 12,000 BTU NAT (3.6 kW NAT) 12,000 BTU NAT (3.6 kW NAT) 8,000 NAT (2.4 kW NAT) 6,000 BTU NAT (1.8 kW NAT) When the conversion is completed, complete the enclosed conversion label and place it next to the rating label. The rating label for your cooktop is located on the exterior bottom panel of the burner box in the right rear corner. PROPER LIGHTING AND SHUTDOWN INSTRUCTIONS 1. To ignite the surface burners, turn the knob counter clockwise to any position. 2. Upon ignition of the surface burner, turn the knob to the desired position, (HI, Med, or Low). 3. To shutdown the burner, turn knob clockwise to the OFF position. 4. In case of failure, shut the gas OFF using the installer supplied manual shut-off valve. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
VGC/CVGC Orifice Locations
B
B
C
D
A
*Burner rates will be lowered by 4% per 1000 ft. above altitudes of 2000 ft.
When the conversion is completed, complete the enclosed conversion label and place it next to the rating
label. The rating label for your cooktop is located on the exterior bottom panel of the burner box in the right
rear corner.
PROPER LIGHTING AND SHUTDOWN INSTRUCTIONS
1.
To ignite the surface burners, turn the knob counter clockwise to any position.
2.
Upon ignition of the surface burner, turn the knob to the desired position, (HI, Med, or Low).
3.
To shutdown the burner, turn knob clockwise to the OFF position.
4.
In case of failure, shut the gas OFF using the installer supplied manual shut-off valve.
Burner
NAT
Left Front (A)
.079 (2.01mm) 044706-000
Left Rear (B
.056 (1.42 mm) 044708-000
Center Rear (C)
.060 (1.52 mm) PB040255
Center Front (C)
.060 (1.52 mm) PB040255
Right Rear (E)
.048 (1.22 mm) 044709-000
Right Front (D)
.042 (1.07 mm) PB040274
Burner
NAT
Left Front (A)
.079 (2.01mm) 044706-000
Left Rear (B)
.064 (1.63 mm) PB040255
Center (B)
.064 (1.63 mm) PB040255
Right Rear (C)
.051 (1.30 mm) 044707-000
Right Front (D)
.042 (1.07 mm) PB040274
Burner
30”W. Model
Burner
36”W. Model
Left Front (A)
18,000 BTU NAT
(5.4 kW NAT)
Left Front (A)
18,000 BTU NAT
(5.4 kW NAT)
Left Rear (B)
12,000 BTU NAT
(3.6 kW NAT)
Left Rear (B)
10,000 BTU NAT
(3.0 kW LP)
Center (B)
12,000 BTU NAT
(3.6 kW NAT)
Center Rear (C
12,000 BTU NAT
(3.6 kW NAT)
Center Front (C)
12,000 BTU NAT
(3.6 kW NAT)
Right Rear (C)
8,000 NAT
(2.4 kW NAT)
Right Rear (E
8,000 NAT
(2.4 kW NAT)
Right Front (D)
6,000 BTU NAT
(1.8 kW NAT)
Right Front (D)
6,000 BTU NAT
(1.8 kW NAT)
VGC/CVGC530
VGSU/CVGSU530
VGC/CVGC536
VGSU/CVGSU536
B
C
E
D
C