Weslo Cardio Glide Plus 975 English Manual - Page 8

Maintenance, Trouble, Shooting

Page 8 highlights

MAINTENANCE AND TROUBLE-SHOOTING Inspect and tighten all parts at least once every three months. Make sure that the Foam Pad (26) is pushed all of the way onto the rod at the front. The CARDIO GLIDE PLUS 975 can be cleaned with a soft, damp cloth. Keep liquids away from the monitor. Do not expose the monitor to direct sunlight or the display may be damaged. When storing the CARDIO GLIDE PLUS 975, remove the batteries from the monitor. 0 26 HOW TO REPLACE THE BATTERIES If the display of the Monitor (1) becomes dim, the two L1154 watch batteries should be replaced. Lift the Monitor off the Frame (6). Disconnect the Sensor Wire (15) from the Monitor. Make sure that the end of the Sensor Wire does not slip into the Frame. Remove the four screws from the back cover of the Monitor and remove the back cover. Be careful not to damage the monitor wire. Push the two old batteries out of the battery clips; be sure to note which way each battery is turned. Insert two new batteries. Reattach the back cover of the Monitor (1). Connect the Sensor Wire (15) to the Monitor. Insert all excess wire into the Frame (6). Press the Monitor onto the Frame (see assembly step 4). HOW TO ADJUST THE MAGNET AND REED SWITCH If the monitor displays incorrect feedback, the Magnet (27) and Reed Switch (15) shoiuld be checked. Pivot the Pedal Frame (32) until the Magnet is aligned with the Reed Switch. Loosen the #8 x 3/4" Screw (18) shown in the inset drawing. Slide the Reed Switch slightly closer to the Magnet. Tighten the #8 x 3/4" Screw. Exercise on the CARDIO GLIDE PLUS 975 for a moment. Repeat until the monitor displays correct feedback. Make sure that the Magnet does not hit the Reed Switch. HOW TO LUBRICATE THE CARDIO GLIDE PLUS 975 Every three months, a small amount of light multi-purpose oil should be applied to the CARDIO GLIDE PLUS 975. Apply a few drops of oil between the dome caps and the frame in the locations shown at the right. Make sure to apply oil to both sides of the CARDIO GLIDE PLUS 975. Screws 15 a 6 e Batteries 32 27 32 27 15 15 ' 18 Apply Oil 8 \

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

MAINTENANCE
AND
TROUBLE
-SHOOTING
Inspect
and
tighten
all
parts
at
least
once
every
three
months.
Make
sure
that
the
Foam
Pad
(26)
is
pushed
all
of
the
way
onto
the
rod
at
the
front.
The
CAR-
DIO
GLIDE
PLUS
975
can
be
cleaned
with
a
soft,
damp
cloth.
Keep
liquids
away
from
the
monitor.
Do
not
expose
the
monitor
to
direct
sunlight
or
the
dis-
play
may
be
damaged.
When
storing
the
CARDIO
GLIDE
PLUS
975,
remove
the
batteries
from
the
monitor.
HOW
TO
REPLACE
THE
BATTERIES
If
the
display
of
the
Monitor
(1)
becomes
dim,
the
two
L1154
watch
batteries
should
be
replaced.
Lift
the
Monitor
off
the
Frame
(6).
Disconnect
the
Sensor
Wire
(15)
from
the
Monitor.
Make
sure
that
the
end
of
the
Sensor
Wire
does
not
slip
into
the
Frame.
Remove
the
four
screws
from
the
back
cover
of
the
Monitor
and
remove
the
back
cover.
Be
careful
not
to
damage
the
monitor
wire.
Push
the
two
old
batteries
out
of
the battery
clips;
be
sure
to
note
which
way
each
battery
is
turned.
Insert
two
new
batteries.
Reattach
the
back
cover
of
the
Monitor
(1).
Connect
the
Sensor
Wire
(15)
to
the
Monitor.
Insert
all
excess
wire
into
the
Frame
(6).
Press
the
Monitor
onto
the
Frame
(see
assembly
step
4).
HOW
TO
ADJUST
THE
MAGNET
AND
REED
SWITCH
If
the
monitor
displays
incorrect
feedback,
the
Magnet
(27)
and
Reed
Switch
(15)
shoiuld
be
checked.
Pivot
the
Pedal
Frame
(32)
until
the
Magnet
is
aligned
with
the
Reed
Switch.
Loosen
the
#8
x
3/4"
Screw
(18)
shown
in
the
inset
drawing.
Slide
the
Reed
Switch
slightly
closer
to
the
Magnet.
Tighten
the
#8
x
3/4"
Screw.
Exercise
on
the
CARDIO
GLIDE
PLUS
975
for
a
moment.
Repeat
until
the
monitor
displays
correct
feedback.
Make
sure
that
the
Magnet
does
not
hit
the
Reed
Switch.
HOW
TO
LUBRICATE
THE
CARDIO
GLIDE
PLUS
975
Every
three
months,
a
small
amount
of
light
multi
-purpose
oil
should
be
applied
to
the
CARDIO
GLIDE
PLUS
975.
Apply
a
few
drops
of
oil
between
the
dome
caps
and
the
frame
in
the
locations
shown
at
the
right.
Make
sure
to
apply
oil
to
both
sides
of
the
CARDIO
GLIDE
PLUS
975.
0
26
15
6
Screws
a
Batteries
e
32
27
15
32
27
15
'
18
Apply
Oil
\
8