Whirlpool G9IXEFMWS Owners Manual - Page 14
Product Data Sheets - prices
UPC - 883049155418
View all Whirlpool G9IXEFMWS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
PRODUCT DATA SHEETS Base Grille Water Filtration System Model WF-L200V Capacity 200 Gallons (757 Liters) Model WF-NL120V Capacity 120 Gallons (454 Liters) System tested and certified by NSF International against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Benzene, p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class III. This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53. Substance Reduction NSF Reduction Average Aesthetic Effects Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum% Average% Reduction Reduction Chlorine Taste/Odor Particulate Class lll* ≥50% ≥85% 1.9 mg/L 49333/mL 2.0 mg/L ± 10% 0.07 mg/L At least 10,000 particles/mL 640/mL** 0.06 mg/L 312/mL >75% 98.7% >75% 99.0% Contaminant Reduction NSF Reduction Average Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum% Average% Reduction Reduction Lead:@ pH 6.5 Lead: @ pH 8.5 0.01mg/L 0.01mg /L 0.14 mg/L† 0.15 mg/L ± 10% 0.15 mg/L† 0.15 mg /L ± 10% 0.0014 mg/L 0.0011 mg/L 99.00% 99.21% 0.0069 mg/L 0.0042 mg/L 95.40%% 97.20% Mercury: @ pH 6.5 Mercury: @ pH 8.5 0.002 mg/L 0.002 mg/L 0.0059 mg/L 0.006 mg/L ± 10% 0.0054 mg/L 0.006 mg /L ± 10% 0.0009 mg/L 0.0004 mg/L 84.74% 0.0007mg /L 0.00043 mg/L 87.03% 93.22% 92.03% Benzene 0.005 mg/L 0.0157 mg/L 0.015 mg/L ± 10% 0.002 mg/L 0.00083 mg/L 87.26% 94.71% p-dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L ± 10% 0.0005 mg/L 0.0005 mg/L 99.76% 99.76% O-Dichlorobenzene 0.60 1.84 1.8 ± 10% 0.20 0.0418 89.13 97.73 Toxaphene 0.003 0.0143 0.015 ± 10% 0.0012 0.0010 91.60 93.00 Ethyl Benzene 0.70 2.00 2.1 ± 10% 0.40 0.085 80.00 95.75 1,2,4- trichlorobenzene 0.07 0.232 0.21 ± 10% 0.0041 0.0016 98.23 99.31 Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C). ■ It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. ■ Model WF-L200V: The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter's rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter's rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement filter L200V / NL120V, part #4396701. 2009 suggested retail price of $34.99 U.S.A./ $45.99 Canada. Prices are subject to change without notice. ■ Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number. ■ Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33° - 100°F (0.6° - 37.8°C) 0.5 GPM (1.9 L/min.) @ 60 psi Model WF-NL120V: Change the water filter every 6 months. Use replacement filter L200V / NL120V, part #4396701. 2009 suggested retail price of $34.99 U.S.A./ $45.99 Canada. Prices are subject to change without notice. ■ The product is for cold water use only. ■ Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. *Class Ill particle size: > 5 to < 15 um **Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. †These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International. 14