Exhaust hoods: ■■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow). Recommended Style: Plan Vent System Choose your exhaust installation type Recommended exhaust installations: Typical installations vent the dryer from the rear of the dryer. Other installations are possible. A B Louvered hood Box hood Acceptable Style: Angled hood Elbows 45° elbows provide better airflow than 90° elbows. Good Better C A. Exhaust hood B. Flexible metal or rigid metal vent C. Elbow Alternate installations for close clearances: Venting systems come in many varieties. Select the best type for your installation. Two close-clearance installations are shown as below. For more information, refer to the manufacturer's instructions. Clamps ■■ Use clamps to seal all joints. ■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct, because they can catch lint. Do not use duct tape. A B A. Over-the-top installation (also available with one offset elbow) B. Periscope installation NOTE: The kits for close clearance alternate installations are available for purchase. For information on ordering, see "Assistance or Service." 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

7
Exhaust hoods:
Must be at least 12
"
(305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended Style:
Louvered hood
Box hood
Acceptable Style:
Angled hood
Elbows
45° elbows provide better airflow than 90° elbows.
Good
Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct, because they can catch lint. Do not use duct tape.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations:
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A
B
C
A. Exhaust hood
B. Flexible metal or rigid metal vent
C. Elbow
Alternate installations for close clearances:
Venting systems come in many varieties. Select the best type
for your installation. Two close-clearance installations are shown
as below. For more information, refer to the manufacturer’s
instructions.
A
B
A. Over-the-top installation
(also available with one offset elbow)
B. Periscope installation
NOTE:
The kits for close clearance alternate installations
are available for purchase. For information on ordering, see
“Assistance or Service.”