Whirlpool TGG222VDB Installation Instructions - Page 12

Gas Conversions

Page 12 highlights

GAS CONVERSIONS 2. Unplug or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A AA. .GGaass pprreessssuurree rreegguulalatotor r IMPORTANT: Do not remove the gas pressure regulator. NOTE: Do not remove the spring beneath the cap. 4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver. NOTE: Gas conversions (from Natural gas to LP gas or from LP gas to Natural gas) must be done by a qualified person. LP Gas Conversion 5. Turn the cap over so that LP is visible. A 6. Reinstall the cap. A. Cap To Convert Surface Burners A To Convert Gas Pressure Regulator 1. Ensure that the manual shutoff valve is in the closed position. A B C A. Shutoff valve in "closed" position B. Gas supply line C. To range 12 B A. Burner cap B. Burner 1. Remove burner grate, burner caps, and burners.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

12
2.
Unplug or disconnect power.
3.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
NOTE:
Do not remove the spring beneath the cap.
4.
Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
5.
Turn the cap over so that LP is visible.
6.
Reinstall the cap.
To Convert Surface Burners
1.
Remove burner grate, burner caps, and burners.
A
B
A. Burner cap
B. Burner
A
A. Cap
GAS CONVERSIONS
LP Gas Conversion
To Convert Gas Pressure Regulator
1.
Ensure that the manual shutoff valve is in the closed position.
NOTE:
Gas conversions (from
N
atural gas to LP gas or from LP
gas to Natural gas) must be done by a qualified person.
A. Gas pressure regulator
A
A
B
C
A. Shutoff valve in “closed” position
B. Gas supply line
C. To range