Whirlpool TGG222VDB Installation Instructions - Page 14

Natural Gas Conversion

Page 14 highlights

Natural Gas Conversion 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. NOTE: Do not remove the spring beneath the cap. 4. Remove the cap from the gas pressure regulator using a flat- blade screwdriver. NOTE: Gas conversions (from Natural gas to LP gas or from LP gas to Natural gas) must be done by a qualified person. 5. Turn the cap over so that N or NAT is visible. A 6. Reinstall the cap. A. Cap To Convert Surface Burners 1. Remove burner grates, burner caps, and burners. A To Convert Gas Pressure Regulator 1. Ensure that the manual shutoff valve is in the closed position. A B C A. Shutoff valve in "closed" position B. Gas supply line C. To range 2. Unplug or disconnect power. 14 B A. Burner cap B. Burner 2. Locate the Natural gas orifice spuds for the top burners in the bag containing literature included with the range. Two Natural gas spuds are stamped "149" and two "125."

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

14
3.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
NOTE:
Do not remove the spring beneath the cap.
4.
Remove the cap from the gas pressure regulator using a flat
-
blade screwdriver.
5.
Turn the cap over so that N or NAT is visible.
6.
Reinstall the cap.
To Convert Surface Burners
1.
Remove burner grates, burner caps, and burners.
2.
Locate the Natural gas orifice spuds for the top burners in the
bag containing literature included with the range. Two
Natural gas spuds are stamped “149” and two “125.”
Natural Gas Conversion
NOTE:
Gas conversions (from
N
atural gas to LP gas or from LP
gas to Natural gas) must be done by a qualified person.
To Convert Gas Pressure Regulator
1.
Ensure that the manual shutoff valve is in the closed position.
2.
Unplug or disconnect power.
A
A. Cap
A
B
A. Burner cap
B. Burner
A
B
C
A. Shutoff valve in “closed” position
B. Gas supply line
C. To range
A
A. Gas pressure regulator