Whirlpool WEC310SAGS Installation Instructions - Page 8
Level Range, Electrical Connection - U.S.A. Only
View all Whirlpool WEC310SAGS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Level Range 1. Place level on the oven bottom, as indicated in one of the two figures below, depending on the size of the level. Check with the level side-to-side and front to back. 3. Depending on your model, remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block. 2. If range is not level, use a wrench or pliers to adjust leveling legs up or down until the range is level. NOTE: Range must be level for satisfactory baking performance and best cleaning results using AquaLift® Self-Clean Technology. Electrical Connection - U.S.A. Only If your home has a 3- or 4-wire receptacle, continue with "Install Using a Power Supply Cord." If your home has a 3- or 4-wire direct connection, go to "Install Using Direct Wire." Install Using a Power Supply Cord OR Remove the top 10-32 hex nut from each of the three terminal blocks and set aside. 4. Assemble a UL Listed strain relief in the opening. A Power Supply Cord Strain Relief 1. Disconnect power. 2. Remove the lower access cover screws located on the back of the range. Pull the bottom of the cover toward you and out to remove cover from range. A. UL Listed strain relief 5. Complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire is not available) Electrical Connection Options A B C A. Mounting tabs (3) B. Lower access cover C. Screws (2) 8