Whirlpool WED6400S Use and Care Manual - Page 4
Installation, Instructions - dryer
UPC - 883049025087
View all Whirlpool WED6400S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
INSTALLATIONINSTRUCTIONS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. • Flat-blade screwdriver • #2 Phillips screwdriver • Adjustable wrench that opens to 1" (2.5 cm) or hex-head socket wrench (for adjusting dryer feet) • Wire stripper (direct wire installations) • Tin snips (new vent installations) • Level • Vent clamps • Caulking gun and compound (for installing new exhaust vent) • Tape measure Parts supplied: Remove parts package from dryer drum. Check that all parts were included. • If you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements." • A sturdy floor to support the total weight (dryer and load) of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered. • A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector. Installation Clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions 4 leveling legs Parts needed: Check local codes. Check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before purchasing parts. Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For information on ordering, please refer to the "Assistance or Service" section of this manual. You may also contact the dealer from whom you purchased your dryer. Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer, Place dryer at least 18 inches (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. You will need • A location that allows for proper exhaust installation. See "Venting Requirements." • A separate 30-amp circuit. 431/2' (110.5 *29¼" (74.3 cm), 29" (73.7 cm) !2¼" (56.5 cm) *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements." Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: • Additional spacing should be considered for ease of installation and servicing. • Additional clearances might be required for wall, door and floor moldings. • Additional spacing should be considered on all sides of the dryer to reduce noise transfer. For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. • Companion appliance spacing should also be considered.