Whirlpool WED7300XW Installation Instructions - Page 16
Connect Vent, Level Dryer
UPC - 883049202747
View all Whirlpool WED7300XW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Connect Vent 1. Connect vent to exhaust outlet Level dryer 1. Level Dryer Place level here Place level here Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp. 2. Move dryer to final location Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. Not Level LEVEL Not Level 2. Adjust leveling legs Move dryer to final location. Avoid crushing or kinking vent. After dryer is in place, remove cardboard from under dryer. If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the floor. 16