Whirlpool WED9290FW Installation Guide - Page 5
Drain System
View all Whirlpool WED9290FW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation spacing for recessed area or closet installation All dimensions show recommended and minimum spacing allowed. ■■Additional spacing should be considered for ease of installation and servicing. ■■Additional clearances might be required for wall, door, floor, moldings, and drain system. ■■Additional spacing should be considered on all sides of the dryer to reduce noise transfer. ■■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ■■Companion appliance spacing should also be considered. Recommended installation clearances (dryer only): Drain System Drain system can be installed using a floor drain, wall standpipe, floor standpipe, or laundry tub. Select method you need. IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain hose should be inside standpipe. Always secure drain hose with cable tie. Floor standpipe drain system 4.5" (114 mm) max. 54" (1372 mm) min. 30" (762 mm) 0" - 5"* (0 mm - 127 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) Without pedestal 4.5" (114 mm) max. 69" (1753 mm) min. 30" (762 mm) 24 in.2 min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) With 15" matching pedestal Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm) diameter to 1" (25 mm) diameter Standpipe Adapter Kit is available. Top of standpipe must be at least 30" (762 mm) high; install no higher than 54" (1.37 m) from bottom of dryer. IMPORTANT: Only 4.5" (114 mm) of drain hose should be inside standpipe; do not force excess hose into standpipe. *NOTE: 0" ( 0 mm) spacing is allowed behind dryer, providing drain hose is not kinked or pinched. Wall standpipe drain system 4.5" (114 mm) Mobile home - Additional installation requirements: This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. See requirements for floor standpipe drain system. 5