Whirlpool WFG510S0AD Installation Guide - Page 14
Gas Conversions
View all Whirlpool WFG510S0AD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
GAS CONVERSIONS Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer. LP Gas Conversion WARNING WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed and engaged. Failure to follow these instructions can result in death or serious burns to children and adults. 1. Turn the manual shutoff valve to the closed position. B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line 2. Unplug range or disconnect power. To Convert Gas Pressure Regulator (Natural Gas to LP Gas) 1. Remove storage drawer, warming drawer or premium storage drawer. See the "Storage Drawer" or "Warming Drawer or Premium Storage Drawer" section. 2. Locate gas pressure regulator at rear of storage drawer, warming drawer, or premium storage drawer compartment. NOTE: On models with a warming drawer or premium storage drawer, an access cover must be removed to access the gas pressure regulator. A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 14