Whirlpool WGT3300XQ Installation Guide - Page 10

Gas Supply Requirements - manual

Page 10 highlights

GAS SUPPLY REQUIREMENTS GAS SUPPLY LINE ■■ Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the washer/dryer. See illustration below. ■■ 1/2" IPS pipe is recommended. ■■ Must include shut-off valve: In the U.S.A.: An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the washer/dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing. In Canada: An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shut-off valve be installed within six (6) ft. (1.8 m) of the washer/dryer. The location should be easy to reach for opening and closing. E C A D B A. 3/8" flexible gas connector B. 3/8" pipe to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Gas shut-off valve. This washer/dryer is equipped with its own permanent, flexible gas connector, design-certified by CSA International, for connecting the washer/dryer to the gas supply line. Flexible gas connector DRYER GAS CONNECTION Option 1 Rigid gas supply line: ■■ Connect your washer/dryer to the rigid gas supply line using an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the washer/dryer gas pipe, as needed to prevent kinking. Option 2 Approved aluminum or copper tubing: ■■ 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft. (6.1 m) if local codes and gas supplier permit. ■■ If you are using natural gas, do not use copper tubing. ■■ Lengths over 20 ft. (6.1 m) should use larger tubing and a different size adapter fitting. ■■ If your washer/dryer has been converted to use LP gas, 3/8" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. GAS SUPPLY CONNECTION REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the washer/dryer gas pipe, as needed, to avoid kinking. ■■ Use only pipe-joint compound. Do not use TEFLON®† tape. BURNER INPUT REQUIREMENTS Elevations up to 10,000 ft (3,048 meters): ■■ The design of this washer/dryer is certified by CSA International for use at altitudes up to 10,000 ft (3,048 m) above sea level at the Btu rating indicated on the model/serial number plate. Burner input adjustments are not required when the washer/dryer is operated up to this elevation. Elevations above 10,000 ft (3,048 meters): ■■ When installed above 10,000 ft. (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation. Gas supply pressure testing ■■ The washer/dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1/2 psi. †®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

10
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve.
GAS SUPPLY LINE
Must include 1/8" NPT minimum plugged tapping accessible
n
for test gauge connection, immediately upstream of the gas
connection to the washer/dryer. See illustration below.
1/2" IPS pipe is recommended.
n
Must include shut-off valve:
n
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the washer/dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1. The location should
be easy to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) ft. (1.8 m)
of the washer/dryer. The location should be easy to reach
for opening and closing.
This washer/dryer is equipped with its own permanent,
flexible gas connector, design-certified by CSA International,
for connecting the washer/dryer to the gas supply line.
A
B
E
D
C
Flexible gas connector
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
DRYER GAS CONNECTION
Option 1
Rigid gas supply line:
Connect your washer/dryer to the rigid gas supply line using
n
an elbow and a 3/8" flare x 3/8" NPT adapter fitting between
the stainless steel gas connector and the washer/dryer gas
pipe, as needed to prevent kinking.
Option 2
Approved aluminum or copper tubing:
3/8" approved aluminum or copper tubing is acceptable for
n
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
If you are using natural gas, do not use copper tubing.
n
Lengths over 20 ft. (6.1 m) should use larger tubing and
n
a different size adapter fitting.
If your washer/dryer has been converted to use LP gas, 3/8"
n
LP compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE:
Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
®†
tape.
GAS SUPPLY CONNECTION REQUIREMENTS
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
n
between the flexible gas connector and the washer/dryer gas
pipe, as needed, to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
n
®†
tape.
BURNER INPUT REQUIREMENTS
Elevations up to 10,000 ft (3,048 meters):
The design of this washer/dryer is certified by CSA
n
International for use at altitudes up to 10,000 ft (3,048 m)
above sea level at the Btu rating indicated on the model/serial
number plate. Burner input adjustments are not required when
the washer/dryer is operated up to this elevation.
Elevations above 10,000 ft (3,048 meters):
When installed above 10,000 ft. (3,048 m) a 4% reduction of
n
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The washer/dryer must be disconnected from the gas supply
n
piping system during pressure testing at pressures greater
than 1/2 psi.
GAS SUPPLY REQUIREMENTS