Performance Data Sheet

Page 26 highlights

PERFORMANCE DATA SHEET Water Filtration System Model P8WB2L/P8RFWB2L Capacity 200 Gallons (757 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42, Standard 53, and Standard 401 for the reduction of contaminants specified on the Performance Data Sheet. This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53 and 401. Substance Reduction Aesthetic Effects Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 / @ pH 8.5 Benzene p-Dichlorobenzene Carbofuran Toxaphene Atrazine Asbestos Live Cysts† Turbidity Lindane Tetrachloroethylene o-Dichlorobenzene Ethylbenzene 1,2,4-Trichlorobenzene 2,4 - D Styrene Toluene Endrin Atenolol Trimethoprim Linuron Estrone Nonylphenol Influent Challenge Concentration Maximum Permissable Product Water Concentration Average% Reduction 2.0 mg/L ± 10% At least 10,000 particles/mL Influent Challenge Concentration 0.15 mg/L± 10% 0.015 mg/L ± 10% 0.225 mg/L ± 10% 0.08 mg/L ± 10% 0.015 ± 10% 0.009 mg/L ± 10% 107 to 108 fibers/L†† 50,000/L min. 11 NTU ± 10% 0.002 ± 10% 0.015 mg/L ± 10% 1.8 mg/L ± 10% 2.1 mg/L ± 10% 0.210 mg/L ± 10% 0.210 mg/L ± 10% 2.0 mg/L ± 10% 3.0 mg/L ± 10% 0.006 mg/L ± 10% 200 ± 20% 140 ± 20% 140 ± 20% 140 ± 20% 1400 ± 20% 50% reduction 85% reduction 97.0% >99.9% Maximum Permissable Product Water Concentration Average% Reduction 0.010 mg/L >99.3% / 98.6% 0.005 mg/L 93.8% 0.075 mg/L 99.8% 0.040 mg/L 81.9% 0.003 mg/L >95% 0.003 mg/L 87.0% 99% >99% 99.95% >99.99% 0.5 NTU 96.9% 0.0002 mg/L >99.2% 0.005 mg/L 96.6% 0.60 mg/L 92.3% 0.70 mg/L 86.9% 0.07 mg/L >99.8% 0.07 mg/L 88.5% 0.1 mg/L 99.6% 1.0 mg/L 93.5% 0.002 mg/L 81.7% 30 ng/L 95.7% 20 ng/L 96.1% 20 ng/L 96.3% 20 ng/L 95.3% 200 ng/L 95.5% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/ incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality. ■ It is important that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. Property damage can occur if all instructions are not followed. ■ The disposable cartridge must be changed at least every 6 months. ■ Use replacement filter P8RFWB2L, part #EDR1RXD1/ EDR1RXD1B. 2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices are subject to change without notice. ■ Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. EPA Est. No. 082047-TWN-001 ■ Refer to the "Warranty" section (in the User Instructions or User Guide) for the Manufacturer's limited warranty, name and telephone number. ■ The filter monitor system measures the amount of water that passes through the filter and alerts you when it is time to replace the filter. Refer to the "Using the Controls" or "Water Filtration System" section (in the User Instructions or User Guide) to learn how to check the water filter status. ■ After changing the water filter, flush the water system. See "Water and Ice Dispensers" or "Water Dispenser" in the User Instructions or User Guide. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate Potable City or Well 30 - 120 psi (207 - 827 kPa) 33° - 100°F (0.6° - 37.8°C) 0.75 gpm (2.84 L/min) @ 60 psi ■ These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. ■ The product is for cold water use only. ■ The water system must be installed in compliance with state and local laws and regulations. *Class I particle size: >0.5 to

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

26
PERFORMANCE DATA SHEET
Water Filtration System
Model P8WB2L/P8RFWB2L Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53 and 401.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F
(20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/
incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace
levels, these compounds can affect the public acceptance/perception of drinking water quality.
It is important that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised. Property damage can occur if all
instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter P8RFWB2L, part #EDR1RXD1/
EDR1RXD1B. 2015 suggested retail price of $49.99 U.S.A./$49.99
Canada. Prices are subject to change without notice.
The filter monitor system measures the amount of water that
passes through the filter and alerts you when it is time to replace
the filter. Refer to the “Using the Controls” or “Water Filtration
System” section (in the User Instructions or User Guide) to learn
how to check the water filter status.
After changing the water filter, flush the water system. See “Water
and Ice Dispensers” or “Water Dispenser” in the User Instructions
or User Guide.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
EPA Est. No. 082047-TWN-001
Refer to the “Warranty” section (in the User Instructions or User
Guide) for the Manufacturer’s limited warranty, name and
telephone number.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against NSF/ANSI
Standard 42, Standard 53, and Standard 401 for the reduction of
contaminants specified on the Performance Data Sheet.
Substance Reduction
Aesthetic Effects
Influent Challenge Concentration
Maximum Permissable Product Water Concentration
Average% Reduction
Chlorine Taste/Odor
Particulate Class I*
2.0 mg/L ± 10%
At least 10,000 particles/mL
50% reduction
85% reduction
97.0%
>99.9%
Contaminant Reduction
Influent Challenge Concentration
Maximum Permissable Product Water Concentration
Average% Reduction
Lead: @ pH 6.5 / @ pH 8.5
0.15 mg/L± 10%
0.010 mg/L
>99.3% / 98.6%
Benzene
0.015 mg/L ± 10%
0.005 mg/L
93.8%
p-Dichlorobenzene
0.225 mg/L ± 10%
0.075 mg/L
99.8%
Carbofuran
0.08 mg/L ± 10%
0.040 mg/L
81.9%
Toxaphene
0.015 ± 10%
0.003 mg/L
>95%
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
87.0%
Asbestos
10
7
to 10
8
fibers/L
††
99%
>99%
Live Cysts
50,000/L min.
99.95%
>99.99%
Turbidity
11 NTU ± 10%
0.5 NTU
96.9%
Lindane
0.002 ± 10%
0.0002 mg/L
>99.2%
Tetrachloroethylene
0.015 mg/L ± 10%
0.005 mg/L
96.6%
o-Dichlorobenzene
1.8 mg/L ± 10%
0.60 mg/L
92.3%
Ethylbenzene
2.1 mg/L ± 10%
0.70 mg/L
86.9%
1,2,4-Trichlorobenzene
0.210 mg/L ± 10%
0.07 mg/L
>99.8%
2,4 - D
0.210 mg/L ± 10%
0.07 mg/L
88.5%
Styrene
2.0 mg/L ± 10%
0.1 mg/L
99.6%
Toluene
3.0 mg/L ± 10%
1.0 mg/L
93.5%
Endrin
0.006 mg/L ± 10%
0.002 mg/L
81.7%
Atenolol
200 ± 20%
30 ng/L
95.7%
Trimethoprim
140 ± 20%
20 ng/L
96.1%
Linuron
140 ± 20%
20 ng/L
96.3%
Estrone
140 ± 20%
20 ng/L
95.3%
Nonylphenol
1400 ± 20%
200 ng/L
95.5%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Potable City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.75 gpm (2.84 L/min) @ 60 psi
*
††
Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.