Plumbing Problems WARNING Excessive Weight Hazard Use two or more people to move and install ice maker. Failure to do so can result in back or other injury. PROBLEM Water Not Entering Drain Properly RECOMMENDED SOLUTIONS If the drain hose is not aligned over the drain, move the ice maker to align the drain. NOTE: Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed, qualified plumber. PERFORMANCE DATA SHEET Ice Maker Water Filtration System Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor. This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42. Substance Reduction Aesthetic Effects NSF Reduction Requirements Average Influent Influent Challenge Maximum Concentration Effluent Average Effluent Minimum % Average % Reduction Reduction Chlorine Taste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81 Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters). ■■ It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. ■■ Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K, Part Number ICE2. Style 1 - When the water filter status display changes from "GOOD" to "ORDER," order a new filter. When the filter indicator reads "REPLACE," it is recommended that you replace the filter. Style 2 - Press FILTER to check the status of your water filter. If the filter indicator light is yellow and the words "ORDER FILTER" appear on the display screen, order a new filter. If the filter indicator light is red, it is recommended that you replace the filter. ■■ Refer to the "Warranty" section for the Manufacturer's name, address and telephone number. ■■ Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply City or Well Water Pressure 30 - 120 psi (207 - 827 kPa) Water Temperature 33°- 100°F (0.6° - 37.8°C) Service Flow Rate 0. 50 gpm (1.89 Lpm) @ 60 psi ■■ These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. ■■ The product is for cold water use only. ■■ Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. ®NSF is a registered trademark of NSF International. 11-Jun-2018 15:29:29 EDT | RELEASED In some European7factories the letter "W" of the part code mentioned herein will be automatically replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

7
Plumbing Problems
PROBLEM
RECOMMENDED SOLUTIONS
Water Not Entering Drain
Properly
If the drain hose is not aligned over the drain, move the ice maker to align the drain.
NOTE:
Service technicians cannot repair plumbing problems outside of the ice maker. Call a licensed,
qualified
plumber.
Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI Standards 42.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
50% reduction
1.9727 mg/L
2.0 mg/L ± 10%
0.71 mg/L
0.7788 mg/L
70.2
72.81
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as
advertised.
Use replacement filter P6RFWG2K, P6RFGEG2K, P6RFKG2K,
Part Number ICE2.
Style 1
– When the water filter status display changes from
“GOOD” to “ORDER,” order a new filter. When the filter indicator
reads “REPLACE,” it is recommended that you replace the filter.
Style 2
– Press FILTER to check the status of your water filter. If
the filter indicator light is yellow and the words “ORDER FILTER”
appear on the display screen, order a new filter. If the filter
indicator light is red, it is recommended that you replace the filter.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33°- 100°F (0.6° - 37.8°C)
Service Flow Rate 0.
50 gpm (1.89 Lpm) @ 60 psi
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
System tested and certified by NSF
International against NSF/ANSI
Standard 42 for the reduction of
Chlorine Taste and Odor.
PERFORMANCE DATA SHEET
®NSF is a registered trademark of NSF International.
11-Jun-2018 15:29:29 EDT | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")