Yamaha CVP-202 Data List - Page 17
INTERNAL CLOCK / EXTERNAL CLOCK Receive only, 6-3-3 XG PARAMETER REQUEST Receive only - clavinova model #
View all Yamaha CVP-202 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
(3-6-2-2) UNIVERSAL NON REALTIME MESSAGE (3-6-2-2-1) GENERAL MIDI SYSTEM ON binary hexadecimal 11110000 F0 Exclusive status 01111110 7E Universal Non-Realtime 01111111 7F ID of target Device 00001001 09 Sub-ID #1=General MIDI Message 00000001 01 Sub-ID #2=General MIDI On 11110111 F7 End of Exclusive or 11110000 F0 Exclusive status 01111110 7E Universal Non-Realtime 0xxxnnnn XN When N is received N=0-F, whichever is received. When N is transmitted N always=0. X = don't care 00001001 09 Sub-ID #1=General MIDI Message 00000001 01 Sub-ID #2=General MIDI On 11110111 F7 End of Exclusive Depending upon the received ON message, the System Mode will be changed to XG. Except MIDI Master Tuning, all control data be reset to default values. This message requires approximately 50ms to execute, so sufficient time should be allowed before the next message is sent. After the GM System ON message is received, message reception of the following will be limited. • Bank Select MSB-LSB in channel 10 will be ignored and the drum voice will be fixed. • Bank Select MSB-LSB except in channel 10 will be ignored except 127/0. • NRPN is not received. When XG SYSTEM ON is received, these restrictions will be cancelled. (3-6-3) XG STANDARD (3-6-3-1) XG PARAMETER CHANGE (3-6-3-1-1) XG SYSTEM ON binary hexadecimal 11110000 F0 01000011 43 0001nnnn 1N 01001100 4C 00000000 00 00000000 00 01111110 7E 00000000 00 11110111 F7 Exclusive status YAMAHA ID Device Number Model ID Address High Address Mid Address Low Data End of Exclusive Depending upon the received ON message, the SYSTEM MODE will be changed to XG.Controllers will be reset, all values of Multi Part and Effect, and All System values denoted by "XG" data within All System will be reset to default values in the table. This message requires approximately 50ms to execute, so sufficient time should be allowed before the next message is sent. (3-6-3-1-2) XG PARMETER CHANGE binary hexadecimal 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0001nnnn 1N Device Number 01001100 4C Model ID 0aaaaaaa AA Address High 0aaaaaaa AA Address Mid 0aaaaaaa AA Address Low 0ddddddd DD Data | | 11110111 F7 End of Exclusive For parameters with data size of 2 or 4, transmit the appropriate number of data bytes. For more information on Address and Parameters, refer to < Table 1-2 > (page 20) and < Table 1-4 > ~ < Table 1-6 > (pages 20-23). The following Parameter Changes are handled. XG System Data Multi Effect 1 Data Multi Part Data Drums Setup Data (3-6-3-2) XG BULK DUMP binary hexadecimal 11110000 F0 01000011 43 0000nnnn 0N 01001100 4C 0bbbbbbb BB 0bbbbbbb BB 0aaaaaaa AA 0aaaaaaa AA 0aaaaaaa AA 0ddddddd DD | | 0ccccccc CC 11110111 F7 Exclusive status YAMAHA ID Device Number Model ID ByteCount ByteCount Address High Address Mid Address Low Data Check sum End of Exclusive For more information on Address and Byte Count, refer to < Table 1-2 > ~ < Table 1-6 > (pages 20-23). The Check Sum value is set such that the sum of Byte Count, Address, Data, and Check Sum has value zero in its seven least significant bits. If the top of the block is appointed to the Address the XG Bulk Dump, Bulk Request will be received. The Block is a unit that consists of the data, arranged in the list, as the Total Size. The following Bulk Dumps are handled. XG System Data Multi Effect 1 Data(Individual effect unit) Multi Part Data(Individual part unit) Drums Setup Data(Individual note unit) System Information(Transmit only) (3-6-3-3) XG PARAMETER REQUEST (Receive only) binary hexadecimal 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0011nnnn 3n Device Number 01001100 4C Model ID 0aaaaaaa AA Address High 0aaaaaaa AA Address Mid 0aaaaaaa AA Address Low 11110111 F7 End of Exclusive For more information on Address and Byte Count refer to < Table 1-2 > (page 20) and < Table 1-4 > ~ < Table 1-6 > (pages 20-23). The following Parameter Requests are handled. XG System Data Multi Effect 1 Data Multi Part Data Drums Setup Data (3-6-3-4) XG DUMP REQUEST (Receive only) binary hexadecimal 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0010nnnn 2n Device Number 01001100 4C Model ID 0aaaaaaa AA Address High 0aaaaaaa AA Address Mid 0aaaaaaa AA Address Low 11110111 F7 End of Exclusive For more information on Address and Byte Count refer to < Table 1-2 > ~ < Table 1-6 > (pages 20-23). The following Dump Requests are handled. XG System Data Multi Effect 1 Data(Individual module unit) Multi Part Data(Individual part unit) Drums Setup Data(Individual note unit) System Information (3-6-4) CLAVINOVA MIDI COMPLIANCE (3-6-4-1) INTERNAL CLOCK / EXTERNAL CLOCK (Receive only) binary hexadecimal 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 01110011 73 Clavinova ID 00000001 01 Clavinova common ID 0000001n 0N N: 2(Internal Clock),3(External Clock) 11110111 F7 End of Exclusive CVP-202 17