Yamaha EF3000iSE Owners Manual - Page 22

Application range, for more details. - inverter b

Page 22 highlights

AE01000 APPLICATION RANGE AC DC Power factor EF3000iSE EF3000iSEB 1 0.8-0.95 0.4-0.75 (Efficiency 0.85) -2,800W -2,240W -950W Rated voltage 12V Rated current 12A q 760-026 NOTE: 9 "-" means below. 9 Application wattage indicates when each device is used by itself. 9 The simultaneous usage of AC and DC power is possible but total wattage should not exceed the rated output. EX: Generator rated output Frequency Power factor 1.0 AC 0.8 DC - 2,800VA -2,650W -2,100W 144W (12V/12A) 9 The overload indicator light 1 comes on when total wattage exceeds the application range. (See page 19 for more details.) cC Be sure the total load is within generator rated output otherwise generator damage will occur. NOTE: Some precision equipment is voltage sensitive and may require a more uniform voltage supply than portable generators provide. Examples include some medical equipment, personal computers, and some inverters that sense peak and RMS voltage values. Consult the precision-equipment vendor before relying on any portable generator to provide power to such equipment. - 17 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

17
AE01000
APPLICATION RANGE
AC
DC
Power factor
1
0.8
0.95
0.4
0.75
(Efficiency 0.85)
EF3000iSE
2,800W
2,240W
950W
EF3000iSEB
Rated voltage
12V
Rated current
12A
NOTE:
9
“–”
means below.
9
Application wattage indicates when each device is
used by itself.
9
The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
9
The overload indicator light
1
comes on when
total wattage exceeds the application range. (See
page 19 for more details.)
c
C
Be sure the total load is within generator rated output otherwise generator damage
will occur.
NOTE:
Some precision equipment is voltage sensitive and may require a more uniform voltage
supply than portable generators provide. Examples include some medical equipment,
personal computers, and some inverters that sense peak and RMS voltage values.
Consult the precision-equipment vendor before relying on any portable generator to pro-
vide power to such equipment.
760-026
q
Generator rated output
2,800VA
Frequency
Power factor
1.0
2,650W
AC
0.8
2,100W
144W
DC
(12V/12A)