Yamaha EF4500iSE Owners Manual - Page 40
Generator won, t produce power, To prevent FIRE HAZARDS
View all Yamaha EF4500iSE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
AE00515 Generator won't produce power •Safety device (AC protector) to "Reset"····Press the AC protector to "Set". A ENGINE DOES NOT START B Turn the engine switch to "ON", then turn the engine switch to "START". And check if the starter motor cranks. C Cranks D Does not crank F Turn the engine switch to "START", and check if the oil warning light comes on. G Does not come on H Comes on L Turn the engine switch to "START" and check the spark plug for spark strength. (See "WARNING"). w 9 To prevent FIRE HAZARDS be sure fuel is not present in the spark plug area. 9 To prevent FIRE HAZARDS be sure to place the spark plug as far way as possible from the spark plug hole and carburetor area. 9 To prevent ELECTRIC SHOCK do not hold spark plug lead with hand while testing. M Engine does not start. N Engine starts. R Check the following 9 Fuel cock clogging 9 Air cleaner element clogging. S Clogged T OK U Clean or Replace; Consult a Yamaha dealer. V Consult a Yamaha dealer. - 35 -