Yamaha MTX-MRX MTX-MRX Editor Users Manual [English] - Page 270

MTX-MRX Editor

Page 270 highlights

Alert list Appendix Number Content Action Type 47 Event [**] could not be transmitted. Check the devices that are connected to the network. Error 50 The UNIT ID is set to "00." Set the UNIT ID to something other than "00." Error 51 Devices with identical UNIT IDs were found connected within the same network. Change the UNIT ID so that there are no duplicates. Error • If an error was shown in the DCP panel, refer to the DCP owner's manual and take 52 A communication error occurred with the [DCP] connection. the appropriate action. • Ensure that the panel ID of the DCP units do not conflict. • Verify that the cables are correctly Error connected and are within the specified length. 53 The DCP[*] connected to the [DCP] connector has been configured differently from the project settings. • Check that the required DCP is connected. • Check whether a different model of DCP Error might be connected. 56 SD memory card was not recognized. Use an SD memory card that complies with the specifications. Error Verify that the specified audio file or folder 58 Unable to play the specified file or folder in the SD player. exists in the SD memory card. There must be at least one playable audio file in the specified Warning folder. Initialize the memory of the device (use rear 60 A preset recall attempt has failed. panel DIP switches 7 and 8). If this does not solve the problem, contact your Yamaha Error dealer. 61 The recall could not be executed because the preset to be recalled when the MTX/ MRX starts up was not found. Specify a preset that exists. No sound will be output unless an appropriate preset is recalled. Error Initialize the memory of the device (use rear 62 A snapshot/snapshot group recall attempt has failed. panel DIP switches 7 and 8). If this does not solve the problem, contact your Yamaha Error dealer. • The Snapshot selected for recall cannot be recalled as no data has been stored to it. 63 The snapshot/snapshot group could not be recalled. • Another device may have been added after snapshots were stored. Please synchronize Warning and check all snapshots/snapshot groups using Editor, edit as necessary and store again. • The Preset selected for recall cannot be recalled as no data has been stored to it. 64 The preset could not be recalled. • Another device may have been added after presets were stored. Please synchronize Warning and check all presets using MTX-MRX Editor, edit as necessary and store again. 65 Invalid parameters set for GPI Check the GPI IN settings and perform IN. synchronization again. Error 66 Invalid parameters set for GPI Check the GPI OUT settings and perform OUT. synchronization again. Error Single/ Continuing Single Continuing Continuing Single Continuing Continuing Single Continuing Continuing Continuing Single Continuing Continuing Continuing 270 MTX-MRX Editor User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

Alert list
Appendix
MTX-MRX Editor
User Guide
270
47
Event [**] co
u
ld not be
transmitted.
Check the devices that are connected to the
network.
Error
Single
50
The U
N
IT ID is set to “00.”
Set the UNIT ID to something other than “00.”
Error
Continuing
51
Devices with identical U
N
IT IDs
were fo
u
nd connected within
the same network.
Change the UNIT ID so that there are no
duplicates.
Error
Continuing
52
A comm
u
nication error
occ
u
rred with the [DCP]
connection.
If an error was shown in the DCP panel,
refer to the DCP owner’s manual and take
the appropriate action.
Ensure that the panel ID of the DCP units
do not conflict.
Verify that the cables are correctly
connected and are within the specified
length.
Error
Single
53
The DCP[*] connected to the
[DCP] connector has been
config
u
red differently from the
project settings.
Check that the required DCP is connected.
Check whether a different model of DCP
might be connected.
Error
Continuing
56
SD memory card was not
recognized.
Use an SD memory card that complies with
the specifications.
Error
Continuing
58
Unable to play the specified file
or folder in the SD player.
Verify that the specified audio file or folder
exists in the SD memory card. There must be
at least one playable audio file in the specified
folder.
Warning
Single
60
A preset recall attempt has
failed.
Initialize the memory of the device (use rear
panel DIP switches 7 and 8). If this does not
solve the problem, contact your Yamaha
dealer.
Error
Continuing
61
The recall co
u
ld not be
exec
u
ted beca
u
se the preset to
be recalled when the MTX/
MRX starts
u
p was not fo
u
nd.
Specify a preset that exists. No sound will be
output unless an appropriate preset is
recalled.
Error
Continuing
62
A snapshot/snapshot gro
u
p
recall attempt has failed.
Initialize the memory of the device (
u
se rear
panel DIP switches 7 and
8
). If this does not
solve the problem, contact yo
u
r Yamaha
dealer.
Error
Continuing
63
The snapshot/snapshot gro
u
p
co
u
ld not be recalled.
The Snapshot selected for recall cannot be
recalled as no data has been stored to it.
Another device may have been added after
snapshots were stored. Please synchronize
and check all snapshots/snapshot groups
using Editor, edit as necessary and store
again.
Warning
Single
64
The preset co
u
ld not be
recalled.
The Preset selected for recall cannot be
recalled as no data has been stored to it.
Another device may have been added after
presets were stored. Please synchronize
and check all presets using MTX-MRX
Editor, edit as necessary and store again.
Warning
Continuing
65
Invalid parameters set for GPI
I
N
.
Check the GPI I
N
settings and perform
synchronization again.
Error
Continuing
66
Invalid parameters set for GPI
OUT.
Check the GPI OUT settings and perform
synchronization again.
Error
Continuing
Number
Content
Action
Type
Single/