Installation procedure 1. Check the strength of the installation location. The wall mounting unit weighs approximately 6 kg (13.23 lbs.), and the wide plasma display unit weights approximately 43 kg (94.8 lbs.). While referring to the wall mounting unit installation dimensions in the diagram below, check the strength of the wall in six installation locations, and add reinforcing if any of these locations are not strong enough. (19/32) 15 450 (17 23/32) 930 (36 39/64) 450 (17 23/32) (19/32) 15 (25/32) 20 490 (19 19/64) 450 (17 23/32) 50 (1 31/32) (3 15/16) 100 50 (1 31/32) Units : mm ( ) : inches (1 3/16) 30 (25/32) 20 NNoottee Used for routing wires behind a wall Wall installation holes (6 locations) • The wall mounting unit has installation holes provided in 24 locations. If the wall material will not allow sufficient strength to be obtained from using six installation holes, use some of the spare holes. However, depending on the construction material used at the place of installation, cracks may develop if the screws are inserted too close to each other. 2. Install the wall mounting unit to the wall. • Install the wall mounting unit so that the arrow shown on the wall mounting unit is pointing upwards. • If it is necessary to embed bolts or nuts beforehand because the wall is made from concrete, use the wall mounting unit itself to determine the correct installation hole positions, or use the dimension diagram to calculate the hole positions. Then embed the M6 bolts or nuts into the holes. Furthermore, when embedding the bolts, allow the bolts to protrude from the wall by 10 mm (13/32 inches) to 15 mm (19/32 inches). Fixing screw NNoottee Installation procedure First screw a bolt into the center-top hole. Use a level gauge to correct the alignment of the wall mounting unit, and then screw bolts into the Fixing screw remaining five holes. Provisionally tighten the fixing screws. If the screws are inserted more than 5 mm (13/64 inches), it will not be possible to install the wide plasma display in the correct position. • Use commercially-available M6 bolts which suit the wall materials for installation to the wall. 4

  • 1
  • 2
  • 3
  • 4
  • 5

4
Installation procedure
The wall mounting unit weighs approximately 6 kg (13.23 lbs.), and the wide plasma display unit weights
approximately 43 kg (94.8 lbs.).
While referring to the wall mounting unit installation dimensions in the diagram below, check the strength of the
wall in six installation locations, and add reinforcing if any of these locations are not strong enough.
• The wall mounting unit has installation holes provided in 24 locations.
If the wall material will not allow sufficient strength to be obtained from using six installation holes, use some of the spare holes.
However, depending on the construction material used at the place of installation, cracks may develop if the screws are
inserted too close to each other.
Note
Note
Note
Note
Installation procedure
First screw a bolt into the center-top
hole.
Use a level gauge to correct the
alignment of the wall mounting unit,
and then screw bolts into the
remaining five holes.
Provisionally tighten the fixing screws.
If the screws are inserted more than
5 mm (
13
/
64
inches), it will not be
possible to install the wide plasma
display in the correct position.
1. Check the strength of the installation location.
2. Install the wall mounting unit to the wall.
Fixing screw
Fixing screw
Install the wall mounting unit so that the arrow shown on the wall mounting unit is pointing upwards.
If it is necessary to embed bolts or nuts beforehand because the wall is made from concrete, use the wall
mounting unit itself to determine the correct installation hole positions, or use the dimension diagram to
calculate the hole positions. Then embed the M6 bolts or nuts into the holes. Furthermore, when embedding
the bolts, allow the bolts to protrude from the wall by 10 mm (
13
/
32
inches) to 15 mm (
19
/
32
inches).
930 (36
39
/
64
)
490 (19
19
/
64
)
450 (17
23
/
32
)
30
20
20
450 (17
23
/
32
)
450 (17
23
/
32
)
100
50 (1
31
/
32
)
15
15
Used for routing wires behind a wall
Units : mm
(
) : inches
(
19
/
32
)
(
19
/
32
)
(3
15
/
16
)
(
25
/
32
)
(
25
/
32
)
(1
3
/
16
)
Wall installation holes (6 locations)
50 (1
31
/
32
)
Use commercially-available M6 bolts which suit the wall materials for installation to the wall.