Click [Next]., Check the QL to update., Restart the QL series., The firmware update is now complete. - ql 5 case

Page 10 highlights

6. Click [Next]. ・ Dante Firmware Update Manager may be blocked by the Windows Firewall. For Windows XP, click [Unblock] in such case. For Windows 7/8, select the [Private Network] checkbox and click [Allow access]. 7. Check the QL to update. Check the version of the update files and the version number indicated in the QL line. ・ If the QL is not indicated, click [Refresh]. If it is still not indicated after that, the computer and the QL are not connected properly. Check that the cable is not loose or disconnected, TCP/IP is properly configured, and the QL is powered on. 8. Click [Start]. The update operation will begin. "Updating(n/m)" appears in the Status field during updating. "Done" is displayed once update is completed. Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device may become inoperative. ・ If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right corner of Dante Firmware Update Manager to exit the program without turning the QL power off, and restart the procedure from the step 4. If update still fails, follow the instructions stated in "About Failsafe Mode" to perform the recovery processing. 9. Restart the QL series. The firmware update is now complete. QL5/QL1 Firmware Update Guide 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

QL5/QL1 Firmware Update Guide
10
6.
Click [Next].
Dante Firmware Update Manager may be blocked by the Windows Firewall. For Windows XP, click [Unblock]
in such case. For Windows 7/8, select the [Private Network] checkbox and click [Allow access].
7.
Check the QL to update.
Check the version of the update files and the version number indicated in the QL line.
If the QL is not indicated, click [Refresh]. If it is still not indicated after that, the computer and the QL are
not connected properly. Check that the cable is not loose or disconnected, TCP/IP is properly configured, and
the QL is powered on.
8.
Click [Start].
The update operation will begin.
Updating(n/m)” appears in the Status field during updating. “Done” is displayed once update is completed.
Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the
cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device
may become inoperative.
If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right
corner of Dante Firmware Update Manager to exit the program
without turning the QL power off
, and
restart the procedure from the step 4. If update still fails, follow the instructions stated in “About Failsafe
Mode” to perform the recovery processing.
9.
Restart the QL series.