Yamaha REX50 REX50 Owners Manual Image - Page 16
Level, Decay, Attack, Release
View all Yamaha REX50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
/ 12. SYMPHONIC / This effect is produced in the same way as the flange effect, but has a "bigger," more sweeping sound. Modulation Frequency (MOD. FRO): 0.1 Hz - 20.0 Hz Sets the speed of the effect variation. Modulation Depth (MOD. DEPTH): 0% - 100% Sets the depth of the effect. / 14. ADR-NOISE GATE / This program uses a "gate" to pass or shut off the input signal in a number of ways. It can be used to pass just a short segment of a longer input signal, or it can be set up to pass only signals that exceed a specified level. In the latter case this program functions as a "noise gate." It is also possible to create reverse gate type effects in which the gain increases gradually after the effect is triggered. (LEVEL) 100% DECAY LVL = 100% DECAY LVL DECAY ATTACK HOLD RELEASE (TIME) Trigger Level (TRG. LEVEL): 1 - 100 Determines the level of the input signal required to trigger "opening" of the gate. At 100% only very high-level input signals will trigger the gate, while at 1% even the tiniest input signal will trigger the gate. Trigger Delay (TRG. DLY): -100 - + 100 ms Produces a delay between the time at which the gate is triggered and that at which it actually opens. If a minus value is programmed, the input signal is delayed so that, effectively, the gate opens before the signal appears. Trigger Mask (TRG. MSK): 5 - 32,000 ms This parameter makes it impossible to re-trigger the gate function until the programmed time has elapsed. Attack Time (ATTACK): 5 - 32,000 ms Determines how long it takes for the gate to open fully from the time it begins to open. Decay Time (DECAY): 5 - 32,000 ms Determines the length of time it takes for the gate envelope to fall to DECAY LEVEL after it is fully open. Decay Level (DECAY LVL): 0 - 100% Determines the level at which the gate remains open for the HOLD TIME. The lower the value, the lower the HOLD gate level. Hold Time (HOLD): 1 - 30,000 ms Determines how long the gate stays open, allowing the signal to pass at the DECAY LEVEL, after the first decay and prior to beginning of the RELEASE TIME. Release Time (RELEASE): 5 - 32,000 ms Determines how long it takes for the gate to close fully after the HOLD TIME has ended. MIDI Trigger (MIDI TRG.): OFF, ON When this parameter is turned ON, a KEY ON EVENT message from an external MIDI keyboard can be used to trigger the gate. A KEY ON EVENT message is transmitted whenever a note on a MIDI keyboard is played. 15