Warning Messages, Information Messages

Page 18 highlights

Troubleshooting Warning Messages The indicators will light and/or flash as shown until the cause is resolved. If the green [SYNC] indicator is unlit, the unit's clock is unconfirmed. SYNC Indicators Description The word clock is not set correctly. Flash Dante Network circuit is broken. Flash x2 Possible Solution Set the clock master and sampling frequency correctly on the Rio-native device or in Dante Controller. Make sure that the Ethernet cables are not removed or short-circuited. Flash x3 Other Dante-compatible devices cannot be found due to an incorrectly-wired Dante Network. Make sure that the Ethernet cables are connected correctly. If the green indicator is flashing, the unit is the clock master. If the green indicator is lit, the unit is the clock slave and the clock is synchronized. SYNC Indicators Description Possible Solution A non-GbE-compatible device is connected. When transferring audio via Dante, use device that supports GbE. Light or flash Light Light or flash Flash The [SECONDARY] connector has taken over communications during redundant network operation. Check the circuit connected to the [PRIMARY] connector. Light or flash Flash x2 An abnormality has occurred on the circuit connected to the [SECONDARY] connector during redundant network operation. Check the circuit connected to the [SECONDARY] connector. Information Messages The indicators will remain lit and/or flashing cyclically to report the status. If the orange [SYNC] indicator is unlit, the unit is operating normally. If the green [SYNC] indicator is unlit, the unit's clock is unconfirmed. SYNC Indicators Description Synchronizing on a Dante network Light Waiting to receive setting data The unit is functioning correctly as the word clock master. Explanation Please wait until started has completed or until the unit has finished synchronization. It may take up to 45 seconds for completion. If START UP MODE is set to REFRESH on the R-series unit, the input/output will be muted until the unit receives setting data after it starts up. The unit is operating as the word clock master. Flash Light The unit is functioning correctly as the word clock slave. The unit is operating as the clock slave and the clock is synchronized. 18 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Troubleshooting
Owner’s Manual
18
Warning Messages
The indicators will light and/or flash as shown until the
cause is resolved.
If the green [SYNC] indicator is unlit, the unit’s clock is
unconfirmed.
If the green indicator is flashing, the unit is the clock
master.
If the green indicator is lit, the unit is the clock slave and the
clock is synchronized.
Information Messages
The indicators will remain lit and/or flashing cyclically to
report the status.
If the orange [SYNC] indicator is unlit, the unit is operating
normally.
If the green [SYNC] indicator is unlit, the unit’s clock is
unconfirmed.
SYNC Indicators
Description
Possible Solution
The word clock is not
set correctly.
Set the clock
master and
sampling frequency
correctly on the
Rio-native device or
in Dante Controller.
Dante Network circuit
is broken.
Make sure that the
Ethernet cables are
not removed or
short-circuited.
Other Dante-compatible
devices cannot be
found due to an
incorrectly-wired Dante
Network.
Make sure that the
Ethernet cables are
connected
correctly.
SYNC Indicators
Description
Possible Solution
A non-GbE-compatible
device is connected.
When transferring
audio via Dante,
use device that
supports GbE.
The [SECONDARY]
connector has taken
over communications
during redundant
network operation.
Check the circuit
connected to the
[PRIMARY]
connector.
An abnormality has
occurred on the circuit
connected to the
[SECONDARY]
connector during
redundant network
operation.
Check the circuit
connected to the
[SECONDARY]
connector.
Flash
Flash x2
Flash x3
Light
Light
or
flash
Flash
Light
or
flash
Flash x2
Light
or
flash
SYNC Indicators
Description
Explanation
Synchronizing on a
Dante network
Please wait until
started has
completed or until
the unit has finished
synchronization.
It may take up to 45
seconds for
completion.
Waiting to receive
setting data
If START UP MODE
is set to REFRESH
on the R-series unit,
the input/output will
be muted until the
unit receives setting
data after it starts
up.
The unit is functioning
correctly as the word
clock master.
The unit is
operating as the
word clock master.
The unit is functioning
correctly as the word
clock slave.
The unit is
operating as the
clock slave and the
clock is
synchronized.
Light
Flash
Light