Zenith SL-4132-MW User Guide - Page 6
Testing
UPC - 016963413221
View all Zenith SL-4132-MW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
TESTING ❒ Turn on the circuit breaker and light switch. Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on wait 1 1/2 minutes. ❒ Set SENSITIVITY to mid position and ON-TIME to TEST position. The detector is less sensitive to motion directly towards it and more sensitive to across motion. Motion Motion Sensor Least Sensitive Most Sensitive TEST 1 5 10 MIN ON-TIME LO - M - HI SENSITIVITY ❒ Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area. Avoid aiming the control at: • Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting daylight may trigger the shut-off feature. Do not point other lights at the sensor. Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops. 150° 6 ft. (1.8 m) 30 ft. (9.1m) Maximum Range Maximum Coverage Angle 240° Sensor Aiming Adjustment Angle ❒ Set the SENSITIVITY as needed.Too much sensitivity may increase false triggering. ❒ Set the amount of TIME you want the light to stay on after motion is detected (1, 5, or 10 minutes). 595-5530-13