Zenith SL-5798-WH-A User Guide - Page 4

Specifications, Test And Adjustment

Page 4 highlights

TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. The detector is most sensitive to motion across its field of view. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes. Motion Motion ❒ Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position. Sensor Least Sensitive Most Sensitive LAMP MODE NORMAL SOFT FLASH ON-TIME DUAL BRITE™ MIN MAX RANGE TEST 1 5 20 MINUTES OFF 3 6 DUSK TO HOUR DAWN Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or unwanted traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 270° 8 ft. (2.4 m) 70 ft. 100 ft. (21 m) (30.5 m) Boosted Maximum Range Maximum Coverage Angle NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance. ❒ Loosen the clamp screw in the sensor ball joint and gently rotate the sensor. Clamp Screw ❒ Walk through the coverage area noting where you are when the lights turn on (also, Ball Joint the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- Aim Sensor age area. Keep the sensor at Down for Short least 1" (2.5 cm) away from Coverage the lamps. ❒ Adjust the RANGE as needed. RANGE set too high may increase false triggering. ❒ Secure the sensor head by tightening the clamp screw. Do not overtighten the screw. Aim Sensor Higher for Long Coverage ❒ Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes). ❒ Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn). ❒ Set the LAMP MODE switch to the desired light turn-on effect (Normal, Soft, Flash). SPECIFICATIONS Range Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature] Sensing Angle Up to 270° Electrical Load Up to 300 Watt Maximum In- candescent [Up to 100 Watt Maximum each lamp holder]. Power Requirements. . 120 VAC, 60 Hz Operating Modes. . . . . TEST, AUTO and MANUAL MODE Lamp Modes Normal, Soft, Flash Time Delay 1, 5, 20 minutes Replacement lamp. . . . T4, 100W maximum G8 halogen bi-pin 120 VAC DualBrite® Timer. . . . . Off, 3, 6 hours, Dusk-to-Dawn  598-1309-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

4
598-1309-01
SPECIFICATIONS
Range
............
Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Sensing Angle
......
Up to 270°
Electrical Load
......
Up to 300 Watt Maximum In-
candescent [Up to 100 Watt
Maximum each lamp holder].
Power Requirements .
120 VAC, 60 Hz
Operating Modes
....
TEST, AUTO and MANUAL
MODE
Lamp Modes
.......
Normal, Soft, Flash
Time Delay
........
1, 5, 20 minutes
Replacement lamp.
.
.
T4, 100W maximum G8 halogen
bi-pin 120 VAC
D
UAL
B
RITE
®
Timer
....
Off, 3, 6 hours, Dusk-to-Dawn
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE:
Sensor has a 1
1
/
2
minute warm up period be-
fore it will detect motion. When first turned on
or when switching modes wait 1
1
/
2
minutes.
Turn the RANGE control to the medium position
(halfway between MIN and MAX),
D
UAL
B
RITE
®
to OFF,
and the ON-TIME control to the TEST position.
Motion
Motion
The detector is most sensitive to motion across its field
of view.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners.
These heat
sources could cause false triggering.
• Areas where
pets or unwanted traffic
may trigger
the control.
Nearby large, light-colored objects
reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
270°
Least Sensitive
Most Sensitive
Sensor
Maximum Range
Maximum
Coverage Angle
100 ft.
(30.5 m)
Boosted
LAMP MODE
NORMAL
SOFT FLASH
ON-TIME
DUAL BRITE™
TEST
1
5
20
MINUTES
OFF
3
6
DUSK TO
HOUR
DAWN
MAX
MIN
RANGE
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.
Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the
D
UAL
B
RITE
®
switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
Set the LAMP MODE switch to the desired light
turn-on effect (Normal, Soft, Flash).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.