ZyXEL Omni 56K USB Plus User Guide - Page 48

Table 4-16 Extended S-Registers ATSn=x, COMMAND, FUNCTION AND DESCRIPTION

Page 48 highlights

Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers "ATSn=x" COMMAND BIT DEC HEX FUNCTION AND DESCRIPTION 0,1 0 0 Even parity 1 1 Odd parity 2 2 No parity 2 0 0 1 stop bit 4 4 2 stop bits 4,3 0 0 10 bit character length 8 8 11 bit character length 16 10 9 bit character length 24 18 8 bit character length 7-5 0 0 Profile 0 as active settings after power on. 32 20 Profile 1 as active settings after power on. 64 40 Profile 2 as active settings after power on. 96 60 Profile 3 as active settings after power on 128 80 Factory default as active settings after power on S16= dec hex Test status register. 0 0 No test in progress. 1 1 Analog Loop-back test in progress. 3 3 Local Digital Loop-back test in process. 6 6 Remote Digital Loop-back test in process. 7 7 Remote Digital Loop-back with self-test in process. 8 8 Analog Loop back with self-test in progress. S17= bit dec hex Bit-mapped register. 4-1 0-30 0-1E Set transmit power level from 0 to -15 dBm. (See also S35b3) (Default *P11) 5 0 0 Normal dial. (Default) 32 20 Reverse dial, go on-line in answer mode. 7, 6 0 0 AT Commands set 64 40 V.25bis command set 128 80 Dumb mode (no command accepted) S18= dec hex Force modem to fix baud rate when answering. 0 0 Disable fixed baud function. 1-46 1-2E Enable baud rate to be fixed when answering. Baud rate value settings (n) the same as S20 S19= dec hex Modem connection mode, same 0-99 0-63 Setting value as 'AT&Nn' command. S20= dec hex DTE speed (bps). Auto detected from AT Command. REF. * * *C0* *C1 *C2 *C3 Z0 Z1 Z2 Z3 Z4* +000 &T0 &T1 &T3 &T6 &T7 &T8 +022 *Pn D DR *I0* *I1 *I2 +000 * +000/&Nn +001 4-20 Command Sets

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
4-20
Command Sets
Table 4-16 Extended S-Registers "ATSn=x"
COMMAND
BIT
DEC
HEX
FUNCTION AND DESCRIPTION
REF.
0,1
0
0
Even parity
1
1
Odd parity
2
2
No parity
*
2
0
0
1 stop bit
*
4
4
2 stop bits
4,3
0
0
10 bit character length
*C0*
8
8
11 bit character length
*C1
16
10
9 bit character length
*C2
24
18
8 bit character length
*C3
7-5
0
0
Profile 0 as active settings after power on.
Z0
32
20
Profile 1 as active settings after power on.
Z1
64
40
Profile 2 as active settings after power on.
Z2
96
60
Profile 3 as active settings after power on
Z3
128
80
Factory default as active settings after power on
Z4*
S16=
dec
hex
Test status register.
+000
0
0
No test in progress.
&T0
1
1
Analog Loop-back test in progress.
&T1
3
3
Local Digital Loop-back test in process.
&T3
6
6
Remote Digital Loop-back test in process.
&T6
7
7
Remote Digital Loop-back with self-test in process.
&T7
8
8
Analog Loop back with self-test in progress.
&T8
S17=
bit
dec
hex
Bit-mapped register.
+022
4-1
0-30
0-1E
Set transmit power level from 0 to -15 dBm. (See also
S35b3) (Default *P11)
*Pn
5
0
0
Normal dial. (Default)
D
32
20
Reverse dial, go on-line in answer mode.
DR
7, 6
0
0
AT Commands set
*I0*
64
40
V.25bis command set
*I1
128
80
Dumb mode (no command accepted)
*I2
S18=
dec
hex
Force modem to fix baud rate when answering.
+000
0
0
Disable fixed baud function.
*
1-46
1-2E
Enable baud rate to be fixed when answering. Baud
rate value settings (n) the same as S20
S19=
dec
hex
+000/&Nn
0-99
0-63
Modem connection mode, same
Setting value as 'AT&Nn' command.
S20=
dec
hex
DTE speed (bps).
Auto detected from AT Command.
+001