PID: 30430 Rev 3.51 March 2006 AMD Athlon™ 64 Processor Power and Thermal Data Sheet Parameter/OPN Notes M odel Number CPUID 8000_0001h EBX [11:6] 1 (BrandID) CPUID 8000_0001h EAX [31:0] 1 (CPUID) FID/VID Status M axVID Field 2 FID/VID Status M axFID Field 2 FID/VID Status StartVID Field 2 FID/VID Status StartFID Field 2 L2 Cache Size Max P-S tate VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #1 5 VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #2 5 VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #3 5 VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #4 5 VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #5 5 VID Code / VID_VDD 3 Thermal Design Power 4 Intermediate P-S tate #6 5 VID Code / VID_VDD 3 Thermal Design Power 4 Min P-S tate VID Code / VID_VDD 3 Thermal Design Power 4 S DA3100AIO3BX 3100+ 26h 00020FC2h 04h 0Ah 06h 0Ah 256 KB 1800 M Hz 06h 1.400 V 59.0 W N/A N/A N/A N/A N/A N/A 1000 M Hz 12h 1.100 V 21.7 W The notes for this table appear on page 67. S DA3300AIO2BX 3300+ 26h 00020FC2h 04h 0Ch 06h 0Ch 128 KB 2000 M Hz 06h 1.400 V 59.0 W 1800 M Hz 08h 1.350 V 49.6 W N/A N/A N/A N/A N/A 1000 M Hz 12h 1.100 V 20.7 W S DA3400AIO3BX 3400+ 26h 00020FC2h 04h 0Ch 06h 0Ch 256 KB 2000 M Hz 06h 1.400 V 59.0 W 1800 M Hz 08h 1.350 V 49.6 W N/A N/A N/A N/A N/A 1000 M Hz 12h 1.100 V 20.7 W . Notes: 1 CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given processor to the P- states that are valid for that processor. Refer to the BIOS and Kernel Developer's Guide for AM D Athlon™ 64 and AM D Opteron™ Processors, order# 26094. 2 FIDVID Status Register, M SR C001_0042h. 3 The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4 Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5 Implementation of this P-state is optional in BIOS. AMD Sempron™ Processor 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95

PID: 30430 Rev 3.51 March 2006
AMD Athlon™ 64 Processor Power and Thermal Data Sheet
67
AMD Sempron™ Processor
The notes for this table appear on page 67.
.
Parameter/OPN
Notes
Model Number
CPUID 8000_0001h EBX [11:6]
(BrandID)
1
CPUID 8000_0001h EAX [31:0]
(CPUID)
1
FID/VID Status MaxVID Field
2
FID/VID Status MaxFID Field
2
FID/VID Status StartVID Field
2
FID/VID Status StartFID Field
2
L2 Cache Size
Max P-State
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #1
5
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #2
5
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #3
5
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #4
5
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #5
5
VID Code / VID_VDD
3
Thermal Design Power
4
Intermediate P-State #6
5
VID Code / VID_VDD
3
Thermal Design Power
4
Min P-State
VID Code / VID_VDD
3
Thermal Design Power
4
SDA3100AIO3BX
3100+
26h
00020FC2h
04h
0Ah
06h
0Ah
256 KB
1800 MHz
06h
1.400 V
59.0 W
N/A
N/A
N/A
N/A
N/A
N/A
1000 MHz
12h
1.100 V
21.7 W
SDA3300AIO2BX
3300+
26h
00020FC2h
04h
0Ch
06h
0Ch
128 KB
2000 MHz
06h
1.400 V
59.0 W
1800 MHz
08h
1.350 V
49.6 W
N/A
N/A
N/A
N/A
N/A
1000 MHz
12h
1.100 V
20.7 W
SDA3400AIO3BX
3400+
26h
00020FC2h
04h
0Ch
06h
0Ch
256 KB
2000 MHz
06h
1.400 V
59.0 W
1800 MHz
08h
1.350 V
49.6 W
N/A
N/A
N/A
N/A
N/A
1000 MHz
12h
1.100 V
20.7 W
1
CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given processor to the P-
states that are valid for that processor. Refer to the BIOS and Kernel Developer’s Guide for AMD Athlon™ 64
and AMD Opteron™ Processors, order# 26094.
2
FIDVID Status Register, MSR C001_0042h.
3
The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data
sheet for details.
4
Thermal Design Power (TDP) is measured under the conditions of Tcase Max, IDD Max, and VDD=VID_VDD,
and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA.
5
Implementation of this P-state is optional in BIOS.
Notes: