Asko T702 User manual Use & Care Guide Asko T702 EN - Page 24

Electrical installation

Page 24 highlights

Installation instructions To connect the exhaust duct to a ventilation outlet, follow the steps below: 1. Connect the exhaust duct to a ventilation ex- haust fitting or to a discharge through the wall. 2. Secure the duct joint to the outlet stub on the machine. 3. Run the duct with as few bends as possible to the point of discharge. Ventilation grill Make sure nothing is blocking the ventill Warning! This appliance shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space or a concealed space of a building. Only a rigid or flexible metal duct shall be used for exhausting. Only a metal ventilation grill shall be used. If the duct is taken to a wall outlet, a ventilation grill shall be fitted to prevent reverse flow of cold air. Fit the ventilation grill to the outside or inside of the wall. If there is only one vent duct from the room, a vent spacer must be fitted. Vent spacer Electrical installation Warning! The receptacle on the rear of the machine is designed to accommodate ASKO washers ONLY (rated 208-240 V.) To use this receptacle, you must use the ready-fitted plug supplied with the washing machine or an equivalent. ASKO washers rated 208-240 V have two internal fuses of 15 A each. The machine should only be connected to a grounded wall socket. Warning! This appliance must be properly grounded. Refer to the "Important Safety Instructions" for grounding instructions. The power supply cord must be grounded. If the machine is to be used in a wet area, the supply must be protected by a residual current device. Connection to a permanently wired supply point must be made only by a qualified electrician. As supplied: Single-phase, 230 V, 60 Hz, 3000W heater rating 30 A circuit required Remove cover to access terminal box. (Requires a 20-Torx screwdriver.) 24 Customer Care Center 1-800-898-1879 www.askousa.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

To connect the exhaust duct to a
ventilation outlet, follow the steps below:
1. Connect the exhaust duct to a ventilation ex-
haust fitting or to a discharge through the wall.
2. Secure the duct joint to the outlet stub on the
machine.
3. Run the duct with as few bends as possible to
the point of discharge.
Ventilation grill
Make sure nothing is
blocking the ventill
Warning!
This appliance shall not be exhausted into a
chimney, a wall, a ceiling, an attic, a crawl space
or a concealed space of a building. Only a rigid
or flexible metal duct shall be used for exhausting.
Only a metal ventilation grill shall be used. If the
duct is taken to a wall outlet, a ventilation grill shall
be fitted to prevent reverse flow of cold air. Fit the
ventilation grill to the outside or inside of the wall.
If there is only one vent
duct from the room, a
vent spacer must be fitted.
Vent spacer
Electrical installation
Warning!
The receptacle on the rear of the machine is de-
signed to accommodate ASKO washers ONLY
(rated 208–240 V.) To use this receptacle, you
must use the ready-fitted plug supplied with the
washing machine or an equivalent.
ASKO washers rated 208–240 V have two internal
fuses of 15 A each.
The machine should only be connected to a
grounded wall socket.
Warning!
This appliance must be properly grounded. Refer
to the “Important Safety Instructions” for grounding
instructions.
The power supply cord must be grounded. If the
machine is to be used in a wet area, the supply
must be protected by a residual current device.
Connection to a permanently wired supply point
must be made only by a qualified electrician. As
supplied: Single-phase, 230 V, 60 Hz, 3000W
heater rating 30 A circuit required
Remove cover to
access terminal box.
(Requires a 20-Torx
screwdriver.)
Customer Care Center
24
1-800-898-1879
www.askousa.com
Installation instructions