Asus RS702D-E6 PS8 User Guide - Page 119

Consistency, Check?, Continue, Abort, continues from zero percent.

Page 119 highlights

3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R Virtual Drive(s) Configured Management Menu LD RAID Size #Stripes StripSz Status Configure 0 10 154494MB 4 64 KB ONLINE Initialize Objects Rebuild Check Consistency Consistency Check? Yes No Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, F10-Check Consistency A progress bar appears on screen. LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R Virtual Drive(s) Configured Management Menu LD RAID Size #Stripes StripSz Configure Initialize 0 1C0C Un1d5e4r49P4rMoBcess 4 64 KB Objects Rebuild VD 0 Consistency Check. Press Esc to Abort. Check Consistency ¦ 85 % Completed Virtual Drives Virtual Drive 0 Status ONLINE The Data On The Drives Is Inconsistency. Repair Done! SPACE-(De)Select, F10-Check Consistency 4. While checking the disk consistency, press to display the following options. • Stop - Stops the consistency check. The utility stores the percentage of disk checked, and when you restart checking, it continues from the last percentage completed rather than from zero percent. • Continue - Continues the consistency check. • Abort - Aborts the consistency check. When you restart checking, it continues from zero percent. 5. When checking is complete, press any key to continue. ASUS RS700D-E6/PS8, RS702D-E6/PS8, RS704D-E6/PS8 6-19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

ASUS RS700D-E6/PS8, RS702D-E6/PS8, RS704D-E6/PS8
6-19
3.
When prompted, use the arrow keys to select
Yes
from the
Consistency
Check?
dialog box, and then press <Enter>.
A progress bar appears on screen.
4.
While checking the disk consistency, press <Esc> to display the following
options.
Stop
- Stops the consistency check. The utility stores the
percentage of disk checked, and when you restart checking,
it continues from the last percentage completed rather than
from zero percent.
Continue
- Continues the consistency check.
Abort
-
Aborts the consistency check. When you restart checking, it
continues from zero percent.
5.
When checking is complete, press any key to continue.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Configured
LD
RAID
Size
#Stripes
StripSz
Status
0
10
154494MB
4
64 KB
ONLINE
Virtual Drives
Virtual Drive 0
Consistency Check?
Yes
No
Select VD
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version
A.08.09161344R
SPACE-(De)Select,
F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Configured
LD
RAID
Size
#Stripes
StripSz
Status
0
10
154494MB
4
64 KB
ONLINE
Virtual Drives
Virtual Drive 0
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
¦
85 % Completed
The Data On The Drives Is Inconsistency. Repair Done!
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version
A.08.09161344R
SPACE-(De)Select,
F10-Check Consistency