Biostar N4SIE-A7 N4SIE-A7 BIOS guide - Page 11

Cache Setup, CPU Feature

Page 11 highlights

N4SIE-A7 Cache Setup These BIOS attempt to load the operating system from the device in the sequence selected in these items. CPU L1&L2 Cache Depending on the CPU/chipset in use, you may be able to increase memory access time with this option. Enabled (default) Enable cache. Disabled Disable cache. CPU L3 Cache Depending on the CPU/chipset in use, you may be able to increase memory access time with this option. Enabled (default) Enable cache. Disabled Disable cache. CPU Feature Thermal Management This option allows you to select the way to control the "Thermal Management." The Choices: Thermal Monitor 1 (Default), Thermal Monitor 2. TM2 Bus Ratio This option represents the frequency (bus ratio of the throttled performance state that will be initiated when the on-diesensor goes from not hot to hot.) Min= 0 Max= 255 Key in a DEC number= The Choices: 0 X (Default) TM2 Bus VID This option represents the voltage of the throttled performance state that will be initiated when the on-diesensor goes from not hot to hot. The Choices: 0.8375V (Default), 0.8375-1.6000. Limit CPUID MaxVal Set Limit CPUID MaxVal to 3, it should be "Disabled" for WinXP. The Choices: Disabled (Default), Enabled C1E Function CPU C1E Function select. The Choices:Auto (Default) Execute Disable Bit The Choices: Enabled (Default), Disabled. Virtualization Technology When enabled, a VMM can utilize the additional hardware capabilities provided by vanderpool Technology. The Choices: Enabled (Default), Disabled. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

N4SIE-A7
10
Cache Setup
These BIOS attempt to load the operating system from the device in the sequence selected in
these items.
CPU L1&L2 Cache
Depending on the CPU/chipset in use, you may be able to increase
memory access time with this option.
Enabled
(default)
Enable cache.
Disabled
Disable cache.
CPU L3 Cache
Depending on the CPU/chipset in use, you may be able to increase
memory access time with this option.
Enabled
(default)
Enable cache.
Disabled
Disable cache.
CPU Feature
Thermal Management
This option allows you to select the way to control the “Thermal Management.”
The Choices: Thermal Monitor 1
(Default), Thermal Monitor 2.
TM2 Bus Ratio
This option represents the frequency (bus ratio of the throttled performance state
that will be initiated when the on-diesensor goes from not hot to hot.)
Min=
0
Max= 255
Key in a DEC number=
The Choices: 0 X
(Default)
TM2 Bus VID
This option represents the voltage of the throttled performance state that will be
initiated when the on-diesensor goes from not hot to hot.
The Choices: 0.8375V
(Default), 0.8375-1.6000.
Limit CPUID MaxVal
Set Limit CPUID MaxVal to 3, it should be “Disabled” for WinXP.
The Choices: Disabled
(Default), Enabled
C1E Function
CPU C1E Function select.
The Choices:Auto
(Default)
Execute Disable Bit
The Choices: Enabled
(Default), Disabled.
Virtualization Technology
When enabled, a VMM can utilize the additional hardware capabilities provided
by vanderpool Technology.
The Choices: Enabled
(Default), Disabled.