Bosch NGM5024UC Installation Instructions - Page 5
General Information, Preparation - cooktop
UPC - 825225858355
View all Bosch NGM5024UC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
General Information Overall Dimensions Width (Side to Side) Depth (Front to Back) Height (Top to Bottom) 30" Models 31" (788 mm) 36" Models 37" (940 mm) 21 1/4" (540 mm) 3 13/16 (97 mm) 21 1/4" (540 mm) 3 13/16 (97 mm) NOTE: These are overall dimensions NOT cutout dimensions. Preparation Electrical Requirements This appliances requires a 60 Hz, 15 Amp, 120 VAC connection. Plan the installation so that the power connection is accessible from the front of the cabinet. Gas Requirements Supply Pressure: • Natural Gas - 7 inches water column (14.9 Millibars) minimum. • Propane Gas -11 inches water column (27.4 Millibars) minimum. The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit. The cooktop is shipped from the factory for use with natural gas. For use with LP conversion kit - Model NEZ1054, must be purchased separately. A qualified technician or installer must do the conversion. Cabinet Requirements Dimension requirements in Figures 1 and 2 are for combustible surfaces. When the surface is protected by a material listed by UL as a Floor Protector and Wall Shield covered with not less than No. 28 MSG sheet metal 0.015 inch (0.38mm) stainless steel, 0.024 inch (0.6mm) aluminum or copper, it is considered noncombustible and some dimensions may be reduced. For a noncombustible surface over the cooktop, the minimum clearance is 24" (61cm) rather than 30" (76cm). • Instructions are based on standard American cabinets 36" high (91cm) x 24" deep (61cm) with a 25" (63cm) countertop. • Provide approximately a 10 square inch opening (65cm2) in the toe kick area or other cabinet area for adequate air inlet to the cabinet if installed with a downdraft. • The maximum depth of cabinet installed above cooktop is 13" (33cm). Depth from Back Wall Cabinet 13" (33cm) max. Hood Depth - 24" (61cm) max. Above Counter - 30" (76 cm) min. to Combustible Surface NGM30 - 30" (76cm) min. NGM36 - 36" (91cm) min. 18" (46cm) min. Left Side 12" (33cm) min. Centered Over Cooktop Rear Wall - 2" (5cm) Right Side 12" (33cm) min. Figure 1: Installed Dimensions (from cooktop edges) NOTE: All measurements given have to be precisely followed. If nonstandard cabinets are used, make sure they are installed with minimum dimensions shown in figure 1 and figure 2. Plan the installation of the unit so that the power cord, gas shut-off valve and gas pressure regulator are accessible from the front of cabinet. English 3