Compaq ProLiant 8500 Compaq Parallel Database Cluster Model PDC/O2000 for Orac - Page 58
Table 2-3, I/O Path Failure and Failover Scenarios in Redundant Fibre Channel Fabrics
View all Compaq ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
2-34 Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide Table 2-3 I/O Path Failure and Failover Scenarios in Redundant Fibre Channel Fabrics for Active/Standby Configurations With One RA4000/RA4100 Array continued Description of Failure Failover Response The Fibre Channel SAN Switch None connected to the standby array controller fails. The Fibre Channel cable connection between a Fibre Host Adapter and the Fibre Channel SAN Switch connected to the active array controller is broken. Secure Path forces a complete failover to the standby I/O path components, including the standby Fibre Host Adapter in each node, the other Fibre Channel SAN Switch, the standby array controller in the RA4000/RA4100 Array, and Fibre Channel cables. The Fibre Channel cable None connection between a Fibre Host Adapter and the Fibre Channel SAN Switch connected to the standby array controller is broken. A Fibre Host Adapter connected to the Fibre Channel SAN Switch that connects to the active array controller fails. Secure Path forces a complete failover to the standby I/O path components, including the standby Fibre Host Adapter in each node, the other Fibre Channel SAN Switch, the standby array controller in the RA4000/RA4100 Array, and Fibre Channel cables. A Fibre Host Adapter connected to None the Fibre Channel SAN Switch that connects to the standby array controller fails.