D-Link DNR-326 User Manual - Page 64
Foreign Object, Stop when found, Search, Missing Object, Lose Focus, Camera Occlusion
View all D-Link DNR-326 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Section 3 - Configuration Foreign Object The alarm triggers when any additional object appears in the defined area on the screen. 1. Define the detection zone by clicking and dragging to draw an area on the image. 2. Modify the sensitivity setting. 3. Set the Interval. 4. Select the Stop when found option. If unchecked, the search tool will list all the events it found, instead of stopping at the moment an event is found. 5. Click the Search button. Missing Object The alarm triggers when the selected object is removed from the defined area on the screen. 1. Define the detection object by clicking and dragging to draw an area on the image. 2. Modify the sensitivity setting. 3. Set the Interval. 4. Check the Stop when found option. If unchecked, the search tool will list all the events it found, instead of stopping at the moment the event found. 5. Click the Search button. Lose Focus The system will inform you when the camera(s) loses focus. Camera Occlusion The alarm triggers when the camera is blocked. D-Link DNR-326 User Manual 60